FILTER
– determines the time of the average current value of input, i.e., the time during which no
actions performed when the input signal is changed. It is used to eliminate the effect of "contact bounce" and
filtering of noise resulted from the impulse induction on the connected conductors. Ranges from 0.1 seconds to
10 seconds.
FUNCTION
– for analog and discrete inputs it is possible to choose the functions, which will
automatically process and generate actions depending on its purpose. The function sets the appropriate flags,
which can be used while processing of events.
[Alarm Button]
– the function sets the flag "Pressing the alarm button", this flag is transmitted in the
structure of the protocol in the block "Status/Tracker parameters/Vehicle" - "Vehicle Condition." When it is
changed to the passive state, the flag is removed. When the input is triggered, the extraordinary packet is
formed. If the input is triggered several times, more data packets will be formed. This flag can be processed by
events.
[Ignition Control]
– the input is connected to the ignition switch to control on/off state of the ignition.
The function sets the "Ignition" flag; this flag is transmitted in the structure of the protocol in the block
Status/Tracker parameters/Vehicle" - "Vehicle Condition." By this, you can counter the moto hours or vehicle
usage time. This flag can be processed by events.
– the input is connected to the car's tachometer. In the active state starts the second timer counting
time, the value of which is transferred to the protocol structure in the block "Monitoring (data)" - "hour meter".
The hour meter is reset to zero and starts counting again when overflown.
– this input change into the active state leads to dialing the first number from the list. If the phone
number is not specified, no action is performed. The function sets the "Call Manager" flag; this flag is
transmitted in the structure of the protocol in the block Status/Tracker parameters/Vehicle" - "Vehicle
Condition." This flag can be processed by events, for example, dial specific numbers or to send an SMS with the
specified text. Repeated change to the active state drops the call (if dialing of a number or a conversation
started). When using the NAVISET HF-1 handsfree, this input function is performed by the button on the
handsfree amplifier, the effect of which is already provided in the configuration (call by connection number 1).
[Arming/disarming] –
the transition of this input to other state changes the state of security, i.e. if the
device is secured, disarming takes place, and vice versa. In the UNDER SECURITY mode the device controls all
inputs with the selected input function "door limit switch" or "standard alarm output." When one of them goes
into an active state, the alarm event is generated that can be processed at the user's discretion in the Event
section.
[Control of headlights] –
the function sets the "BS Lights" flag, this flag is transmitted in the structure
of the protocol in the block Status/Tracker parameters/Vehicle" - "Vehicle Condition." When going to the
passive state, the flag is removed. When the input is triggered, the extraordinary data packet is formed. If the
input is triggered several times, more data packets will be formed. This flag can be processed by events.
[Seat belt control] –
the function sets the "belt driver" flag, this flag is transmitted in the structure of
the protocol in the block Status/Tracker parameters/Vehicle" - "Vehicle Condition." When going to the passive
state, the flag is removed. When the input is triggered, the extraordinary data packet is formed. If the input is
triggered several times, more data packets will be formed. This flag can be processed by events.
[Driver presence sensor ] -
The function does not set any flags, processed only by events.
[Trigger of ABS] -
function sets "the ABS" flag, this flag is transmitted in the structure of the protocol in
the block Status/Tracker parameters/Vehicle" - "Vehicle Condition." When going to the passive state, the flag is
removed. When the input is triggered, the extraordinary data packet is formed. If the input is triggered several
times, more data packets will be formed. This flag can be processed by events.