EXAMPLE: COM21 1234,1,2,3,150,50,3,1,5
After the command is executed, the confirmation “Filter changed”
will come
If you send an SMS
COM21 1234,?
Current parameters will come in return.
COM22 PASS,TIMEOUT,TIME1,TIME2,EVENT
Set the parameters of transmission while
standing
PASS – is a current password set in the device. Factory default value
is 1234.
TIMEOUT – the duration of the first interval (1 -255)
TIME1, TIME2 – point recording intervals at the standstill,
respectively, 1 and 2 (0 - 65535)
EVENT – record on events upon the expiry of the interval TIMEOUT,
1-on, 0 – off.
EXAMPLE: COM22 1234,30,120,120,0
After the command is executed the confirmation “Data changed”
will come
If you send an SMS
COM22 1234,?
Current parameters will come in return.
COM23
PASS,ACCEL,TIMETOPARK,MOVETIME,MOVEDIST
Accelerometer response, parameters в
движении
PASS – is a current password set in the device. Factory default value
is 1234.
ACCEL – accelerometer response (0 - 65535)
TIMETOPARK - transition time to the "stdadstill" mode (0 - 65535)
MOVETIME - record time on the move
MOVEDIST - distance record while moving
EXAMPLE: COM22 1234,800,60,30,50
After the command is executed the confirmation “Data changed”
will come
If you send an SMS
COM23 1234,?
Current parameters will come in return.
COM24
PASS,FLINE,DELTA,MINSPEDANGLE,ANGLE,FEVOL
Set the parameters of tracking
PASS – is a current password set in the device. Factory default value
is 1234.
FLINE – Filtration on a straight section (0-off, 1 on)
DELTA - angle of leeway (0 - 360)
MOVETIME - record time on the move
MINSPEEDANGLE - minimum speed of the drawing on turns (0-250)
ANGLE – angle of the drawing on turns
FEVOL – filtration when rebuilding (0-off, 1-on)
EXAMPLE: COM24 1234,0,5,3,7,0
After the command is executed the confirmation “Data changed”
will come
If you send an SMS
COM24 1234,?
Current parameters will come in return.
COM90 PASS
Reset to the factory settings
PASS – is a current password set in the device. Factory default value
is 1234.
EXAMPLE: COM90 1234
After the command is executed the confirmation “Default settings”
will come
COM97 PASS
Delete a track from the device memory
PASS – is a current password set in the device. Factory default value
is 1234.
EXAMPLE: COM97 1234
After the command is executed the confirmation TRACK DELETED
will come
COM98 PASS
Reboot the device
PASS – is a current password set in the device. Factory default value
is 1234.
EXAMPLE: COM98 1234
COM99 PASS,IP,PORT,DAY
Update of FW according to GPRS
PASS – is a current password set in the device. Factory default value
is 1234.
IP – IP address of the remote server of firmware update
PORT - IP port of the remote update server
DAY - the number of months of automatic update, takes values from
0 to 31. The value different from zero enables the automatic update,
the value equal to zero - prohibits.
EXAMPLE: COM99 1234,255.255.255.255,5001,10
After update the confirmation “Firmware load” will come
NOTE!
The factory value of password is 1234. Additional functions can only be adjusted by means of
сonfigurator program by direct connection or remotely via GPRS.