NX100 Pre-installation Manual
Planning control/monitor connections
Issue 3.2 2017-03-31
Page 8-5
Remote inputs
You can connect to up to 16 remote inputs, which allow you to remotely control various operational
characteristics of the transmitter. Each input is mapped to a control that is user defined. See
for a list of input options and their functional descriptions. See
the associated input terminals and control switches (see
“Backup control switches” on page 8-8
the remote interface PWB (A11A4). Refer to the
NX100 Operations and Maintenance Manual
for
instructions on changing the remote input settings, including which setting is assigned to the input
pin and which logic is required to change (activate, enable, etc.) the setting.
Unless otherwise noted these inputs are only accepted by the transmitter if the remote/local status is
set to remote. That setting can only be made by a local user using the front panel AUI.
The external remote input circuits interface with the transmitter via the remote interface PWB and
then with opto couplers on the control/interface PWB. The opto couplers buffer and isolate the
external circuits and prevent any unwanted transients from affecting transmitter operation while
remote control is selected on the transmitter.
Table 8.1: Remote Inputs - Selection Options
Remote Input
Function
RF On
Same as pressing the AUI RF On button. Tells the transmitter to provide RF power if possible.
Provide an active pulse to select.
RF Off
Same as pressing the AUI RF Off button. Tells the transmitter to disable RF power. Provide an
active pulse to select.
Reset
Causes a system reset. Provide an active pulse to select.
Increase RF Power
Increases the power level of the current mode. Send an active pulse to increase the power
slightly, or send a signal of greater duration to continue increasing power.
Decrease RF Power
Decreases the power level of the current mode. Send an active pulse to decrease the power
slightly, or send a signal of greater duration to continue decreasing power.
Exciter A Select
Causes a changeover to select exciter A as the active exciter. Provide an active pulse to select.
Exciter B Select
Causes a changeover to select exciter B as the active exciter. Provide an active pulse to select.
Auto Changeover
Enables or disables automatic exciter changeover. Provide an active pulse to toggle between
selecting automatic or manual.
Scheduler On/Off
Enables or disables the automatic mode scheduler. Provide an active pulse to toggle between
selecting automatic or manual.
Max Power Lockout
Select
Selects the associated power lockout limit (1 to 8) as active. Provide an active pulse to select.
Preset Select
Selects the associated user-named mode as the active preset. Provide an active pulse to
select.
Содержание NX100
Страница 1: ...NX100 Transmitter Pre installation Manual Document NHB NX100 PRE Issue 3 2 2017 03 31 Status Standard...
Страница 2: ......
Страница 4: ......
Страница 8: ...NX100 Pre installation Manual Page 1 viii Issue 3 2 2017 03 31...
Страница 10: ...NX100 Pre installation Manual Page x Issue 3 2 2017 03 31...
Страница 22: ...NX100 Pre installation Manual Page xxii Issue 3 2 2017 03 31...
Страница 24: ...NX100 Pre installation Manual Page xxiv Issue 3 2 2017 03 31...
Страница 28: ...NX100 Pre installation Manual Description Page 1 4 Issue 3 2 2017 03 31...
Страница 32: ...NX100 Pre installation Manual Pre installation tasks Page 2 4 Issue 3 2 2017 03 31...
Страница 42: ...NX100 Pre installation Manual Physical requirements Page 3 10 Issue 3 2 2017 03 31...
Страница 60: ...NX100 Pre installation Manual Electrical requirements Page 5 10 Issue 3 2 2017 03 31...
Страница 85: ...NX100 Pre installation Manual Planning control monitor connections Page 8 16 Issue 3 2 2017 03 31...
Страница 89: ...NX100 Pre installation Manual Parts and tools Page 9 4 Issue 3 2 2017 03 31...
Страница 95: ...NX100 Pre installation Manual Pre installation assistance Page 10 6 Issue 3 2 2017 03 31...
Страница 98: ......