Planning control/monitor connections
Page 8-4
Issue 3.2 2017-03-31
External PDM inhibit
You can connect an external PDM inhibit to terminal block TB1 (terminals 5 through 8) of the
control/interface PWB (A11A1), located on the exciter panel behind the front door. This connection
allows you to configure an external PDM inhibit circuit that provides an emergency RF inhibit
control for the NX100. This circuit can be configured as single-ended or differential, using user-
provided shorting jumpers on terminal block TB1 (see
).
Single Ended Input (Internal dc supply).
If you are using the transmitter's 15 V as the current
source for the PDM inhibit circuit, install a shorting jumper between the
+15V
terminal (TB1-5) and
the
+
terminal (TB1-6) and connect your external PDM inhibit circuit between the
GND
terminal
(TB1-8) and the
–
terminal (TB1-7).
The external PDM inhibit circuit must present a short circuit (low impedance) between TB1-8 and
TB1-7 when the RF output requires inhibition. It must present an open circuit for normal operation.
Differential Input (External dc supply).
If you are using an external dc supply (capable of
providing between 12 V and 25 V) as the current source for the external PDM inhibit circuit, connect
the supply’s positive output to the
+
terminal (TB1-6) and the supply’s ground (negative) output to
the
–
terminal (TB1-7), via the external PDM inhibit circuit. No shorting jumper is required.
The external PDM inhibit circuit must present a short circuit (low impedance) between TB1-8 and
TB1-7 when the RF output requires inhibition. It must present an open circuit for normal operation.
Содержание NX100
Страница 1: ...NX100 Transmitter Pre installation Manual Document NHB NX100 PRE Issue 3 2 2017 03 31 Status Standard...
Страница 2: ......
Страница 4: ......
Страница 8: ...NX100 Pre installation Manual Page 1 viii Issue 3 2 2017 03 31...
Страница 10: ...NX100 Pre installation Manual Page x Issue 3 2 2017 03 31...
Страница 22: ...NX100 Pre installation Manual Page xxii Issue 3 2 2017 03 31...
Страница 24: ...NX100 Pre installation Manual Page xxiv Issue 3 2 2017 03 31...
Страница 28: ...NX100 Pre installation Manual Description Page 1 4 Issue 3 2 2017 03 31...
Страница 32: ...NX100 Pre installation Manual Pre installation tasks Page 2 4 Issue 3 2 2017 03 31...
Страница 42: ...NX100 Pre installation Manual Physical requirements Page 3 10 Issue 3 2 2017 03 31...
Страница 60: ...NX100 Pre installation Manual Electrical requirements Page 5 10 Issue 3 2 2017 03 31...
Страница 85: ...NX100 Pre installation Manual Planning control monitor connections Page 8 16 Issue 3 2 2017 03 31...
Страница 89: ...NX100 Pre installation Manual Parts and tools Page 9 4 Issue 3 2 2017 03 31...
Страница 95: ...NX100 Pre installation Manual Pre installation assistance Page 10 6 Issue 3 2 2017 03 31...