RF output requirements
Page 6-4
Issue 3.2 2017-03-31
Antenna system
Ensure that the antenna system meets or exceeds the standards specified in EIA Standard TR-101-A,
paragraph 8(b) (see below for the specific requirement), with a normal impedance of 50 ohms at the
carrier frequency.
•
The impedance (resistance and reactance) characteristics of the normal load shall be such
that when the operating carrier frequency changes by ± 5 kHz, the resistance will be within
5% of the resistance at the carrier frequency, and the reactance (adjusted to zero at the carrier
frequency), will be within ± 18% of the resistance at the carrier frequency. When the carrier
frequency changes by ± 10 kHz, the corresponding limits of permissible variation for resis-
tance and reactance are 10% and 35% respectively.
The transmitter will operate with a maximum VSWR of 1.5:1, or with sideband VSWRs of up to 2:1
when the carrier frequency impedance is 50 ohms. However, overall system performance degrades as
the VSWR increases.
Advances in digital modulation schemes like IBOC and DRM systems require better performance
from antenna systems. To ensure the proper operation during digital broadcasting, ensure that the
VSWR does not exceed the values recommended by each standard.
In order to achieve the proper sideband symmetry (Hermitian symmetry) needed for IBOC or DRM
operation, you may need to adjust the tuning of the antenna system to balance the impedances at the
sidebands. You must perform a full impedance sweep of the antenna system before broadcasting
IBOC or DRM. This also requires information about the transmitter’s phase versus frequency
characteristic for Hermitian symmetry at the power amplifier. This information is provided with the
transmitter at time of shipment. For assistance relating to IBOC or DRM transmitter requirements,
contact Nautel Customer Support.
Note:
Hermitian symmetry may not be required for DRM if the VSWR across the bandwidth of the
transmitted signal is very low. Contact Nautel for recommendations.
Содержание NX100
Страница 1: ...NX100 Transmitter Pre installation Manual Document NHB NX100 PRE Issue 3 2 2017 03 31 Status Standard...
Страница 2: ......
Страница 4: ......
Страница 8: ...NX100 Pre installation Manual Page 1 viii Issue 3 2 2017 03 31...
Страница 10: ...NX100 Pre installation Manual Page x Issue 3 2 2017 03 31...
Страница 22: ...NX100 Pre installation Manual Page xxii Issue 3 2 2017 03 31...
Страница 24: ...NX100 Pre installation Manual Page xxiv Issue 3 2 2017 03 31...
Страница 28: ...NX100 Pre installation Manual Description Page 1 4 Issue 3 2 2017 03 31...
Страница 32: ...NX100 Pre installation Manual Pre installation tasks Page 2 4 Issue 3 2 2017 03 31...
Страница 42: ...NX100 Pre installation Manual Physical requirements Page 3 10 Issue 3 2 2017 03 31...
Страница 60: ...NX100 Pre installation Manual Electrical requirements Page 5 10 Issue 3 2 2017 03 31...
Страница 85: ...NX100 Pre installation Manual Planning control monitor connections Page 8 16 Issue 3 2 2017 03 31...
Страница 89: ...NX100 Pre installation Manual Parts and tools Page 9 4 Issue 3 2 2017 03 31...
Страница 95: ...NX100 Pre installation Manual Pre installation assistance Page 10 6 Issue 3 2 2017 03 31...
Страница 98: ......