NOTES:
(A) 50ms Loop Response only available for zones 1-8.
(B) 2-wire Smoke Detectors only available for zones 7 & 8.
(C) If Fire Alarm Verification is selected, then Fire must also be selected.
DEFAULTS:
The zone options indicated are automatically set after exiting the Easy Menu Driven Mode.
•
Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown
and
Zone Area 1
are enabled for the total number of zones entered in “
# OF ZONES IN AREA1 ENTER # ZONES
”.
•
Alarm Telco 1
is enabled for the zone number(s) entered in “
REPORT ALL ZONES TO CENTRAL ZONES? Y/N
”.
•
Entry/Exit 1
and
Chime
are enabled for the zone number(s) entered in “
ENTRY/EXIT ZONES ENTER ZONE #
”.
•
Exit/Entry Follower
and
Interior Bypass
are enabled for the zone number(s) entered in “
INTERIOR ZONES ENTER ZONE #
”.
•
Pulse Alarm Output
is enabled for the zone number(s) entered in “
FIRE ZONES ENTER ZONE #
” or “
2-WIRE FIRE ZNS ENTER ZONE #
”.
•
Fire
is enabled for the zone number(s) entered in “
FIRE ZONES ENTER ZONE #
”.
•
2-Wire Smoke Detector is enabled for the zone number(s) entered in “
2-WIRE FIRE ZNS ENTER ZONE #
”.
ZONE OPTIONS - ZONES 17 TO 32 (ADDRESS 0601-0705)
(Address Location 0530 can only be programmed as “blank (•) blank
(•)”, “4 blank (•)”, “8 blank (•)” or “C blank (•)”.
!
1
!
4
!
4
!
4
!
4
!
2
!
2
!
2
!
2
Zone Options / Zones 17-32
ZONE OPTIONS
ZONES 29-32
LEFT DATA VALUES
(CIRCLE
"
)
ADDRESS
ZONES 25-28
RIGHT DATA VALUES
(CIRCLE
"
)
ZONES 21-24
LEFT DATA VALUES
(CIRCLE
"
)
ADDRESS
ZONES 17-20
RIGHT DATA VALUES
(CIRCLE
"
)
ZN32 ZN31 ZN30 ZN29 L ADDR R ZN28 ZN27 ZN26 ZN25 ZN24 ZN23 ZN22 ZN21 L ADDR R ZN20 ZN19 ZN18 ZN17
$
%
Priority
8
4
2
1
0656
8
4
2
1
8
4
2
1
0601
8
4
2
1
Priority with Bypass
8
4
2
1
0657
8
4
2
1
8
4
2
1
0602
8
4
2
1
Auto-Bypass
8
4
2
1
0658
8
4
2
1
8
4
2
1
0603
8
4
2
1
$
%
Selective Bypass
8
4
2
1
0659
8
4
2
1
8
4
2
1
0604
8
4
2
1
Keyswitch Arming
8
4
2
1
0660
8
4
2
1
8
4
2
1
0605
8
4
2
1
Auto-Bypass Re-entry
8
4
2
1
0661
8
4
2
1
8
4
2
1
0606
8
4
2
1
Pre-Alarm Warning
8
4
2
1
0662
8
4
2
1
8
4
2
1
0607
8
4
2
1
Never Arm
8
4
2
1
0663
8
4
2
1
8
4
2
1
0608
8
4
2
1
24-Hour Zone
8
4
2
1
0664
8
4
2
1
8
4
2
1
0609
8
4
2
1
$
%
Alarm Output
8
4
2
1
0665
8
4
2
1
8
4
2
1
0610
8
4
2
1
$
Pulsed Alarm Output
8
4
2
1
0666
8
4
2
1
8
4
2
1
0611
8
4
2
1
PGM1 Output
8
4
2
1
0667
8
4
2
1
8
4
2
1
0612
8
4
2
1
PGM2 Output
8
4
2
1
0668
8
4
2
1
8
4
2
1
0613
8
4
2
1
$
Entry/Exit 1
8
4
2
1
0669
8
4
2
1
8
4
2
1
0614
8
4
2
1
Entry/Exit 2
8
4
2
1
0670
8
4
2
1
8
4
2
1
0615
8
4
2
1
$
Exit/Entry Follower
8
4
2
1
0671
8
4
2
1
8
4
2
1
0616
8
4
2
1
$
&
Auto Reset
8
4
2
1
0672
8
4
2
1
8
4
2
1
0617
8
4
2
1
$
&
Swinger Shutdown
8
4
2
1
0673
8
4
2
1
8
4
2
1
0618
8
4
2
1
$
Chime
8
4
2
1
0674
8
4
2
1
8
4
2
1
0619
8
4
2
1
Abort Delay
8
4
2
1
0675
8
4
2
1
8
4
2
1
0620
8
4
2
1
Power-up Delay
8
4
2
1
0676
8
4
2
1
8
4
2
1
0621
8
4
2
1
Day Zone Open
8
4
2
1
0677
8
4
2
1
8
4
2
1
0622
8
4
2
1
Day Zone Short
8
4
2
1
0678
8
4
2
1
8
4
2
1
0623
8
4
2
1
Alarm on Day Zone
8
4
2
1
0679
8
4
2
1
8
4
2
1
0624
8
4
2
1
$
Alarm Telco 1
8
4
2
1
0680
8
4
2
1
8
4
2
1
0625
8
4
2
1
Alarm Restore 1
8
4
2
1
0681
8
4
2
1
8
4
2
1
0626
8
4
2
1
Trouble Telco 1
8
4
2
1
0682
8
4
2
1
8
4
2
1
0627
8
4
2
1
Trouble Restore 1
8
4
2
1
0683
8
4
2
1
8
4
2
1
0628
8
4
2
1
Alarm Telco 3
8
4
2
1
0684
8
4
2
1
8
4
2
1
0629
8
4
2
1
Alarm Restore 3
8
4
2
1
0685
8
4
2
1
8
4
2
1
0630
8
4
2
1
Trouble Telco 3
8
4
2
1
0686
8
4
2
1
8
4
2
1
0631
8
4
2
1
Trouble Restore 3
8
4
2
1
0687
8
4
2
1
8
4
2
1
0632
8
4
2
1
No EOL Resistor
8
4
2
1
0688
8
4
2
1
8
4
2
1
0633
8
4
2
1
Trouble on Open
8
4
2
1
0689
8
4
2
1
8
4
2
1
0634
8
4
2
1
Trouble on Short
8
4
2
1
0690
8
4
2
1
8
4
2
1
0635
8
4
2
1
$
Zone Area 1
8
4
2
1
0691
8
4
2
1
8
4
2
1
0636
8
4
2
1
Zone Area 2
8
4
2
1
0692
8
4
2
1
8
4
2
1
0637
8
4
2
1
Interior (Stay) Bypass
8
4
2
1
0693
8
4
2
1
8
4
2
1
0638
8
4
2
1
Keypad Sounder on Alarm
8
4
2
1
0694
8
4
2
1
8
4
2
1
0639
8
4
2
1
$
Fire (C)
8
4
2
1
0696
8
4
2
1
8
4
2
1
0641
8
4
2
1
Fire Alarm Verification
(C)
8
4
2
1
0697
8
4
2
1
8
4
2
1
0642
8
4
2
1
Zone ANDing Group 1
8
4
2
1
0699
8
4
2
1
8
4
2
1
0644
8
4
2
1
Zone ANDing Group 2
8
4
2
1
0700
8
4
2
1
8
4
2
1
0645
8
4
2
1
Zone ANDing Group 3
8
4
2
1
0701
8
4
2
1
8
4
2
1
0646
8
4
2
1
Zone ANDing Group 4
8
4
2
1
0702
8
4
2
1
8
4
2
1
0647
8
4
2
1
Sensor Watch
8
4
2
1
0703
8
4
2
1
8
4
2
1
0648
8
4
2
1
RESERVED
8
4
2
1
0704
8
4
2
1
8
4
2
1
0649
8
4
2
1
Chime 2
8
4
2
1
0705
8
4
2
1
8
4
2
1
0650
8
4
2
1
$
When the Easy Program Menu is used, these features are enabled by default.
%
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
&
Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.