GEM-P1632 Programming Instructions
L
NAPCO Security Systems
!
Page 24
SYSTEM DELAYS & TIMEOUTS (ADDRESS 0000-0002, 0711, 0715, 1059 & 1179)
S
ys
tem Dela
ys
&
Timeouts
!
1. Select delay/timeout (0-255 sec.) from the table shown.
!
2. Enter in corresponding address locations above (left and right digits).
!
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20 sec.
B. Divide it by 16
!
4. Press
U
or
D
to save.
EXIT/ENTRY DELAYS:
Apply only to zones programmed with the following options “Exit/
Entry 1, Exit/Entry 2, Exit/Entry Follower”.
For UL Installations, the maximum exit delay is
60 seconds and the maximum entry delay is 45 seconds.
NOTE:
Sensor Watch Time
Options are similar to above table, except in hours.
1 Quotient Left Digit
16 20
16
4 Remainder Right Digit
SYSTEM DELAYS & TIMEOUTS (ADDRESS 0716 & 0717)
DEFAULTS:
The defaults shown on this
page and on the following pages are
automatically set after exiting the Easy
Menu Driven Mode.
!
1. Select delay/timeout from the table shown.
!
2. Enter in corresponding address locations above (left and right digits).
!
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20
B. Divide it by 16
!
4. Press
U
or
D
to save.
1 Quotient Left Digit
16 20
16
4 Remainder Right Digit
PROGRAMMING STEPS:
1. Lookup desired Programming Option by
Address Location (highlighted in black).
2. Select the programming option data entry
from the tables shown.
3. Enter the selected data entry in the boxes
shown.
4. For more information on a programming
option refer to the Glossary at the end of
this manual.
EXIT
ADDRESS 0000
DELAY
LEFT RIGHT
(sec.)
[Default = 3 C]
ENTRY
ADDRESS 0001
DELAY 1
LEFT RIGHT
(sec.)
[Default = 1 E]
ENTRY
ADDRESS 0002
DELAY 2
LEFT RIGHT
(sec.)
[Default = 1 E]
PGM2 Output
ADDRESS 0711
Access Cntrl
LEFT RIGHT
Timeout (sec.)
[Default = blank (•) blank (•)]
ABORT
ADDRESS 0715
DELAY
LEFT RIGHT
(sec.)
[Default = 1 E]
Sensor Watch
ADDRESS 1059
Time
LEFT RIGHT
(Hrs.)
[Default = 24 HRS = 1 8
Report Cancel
ADDRESS 1179
Window
LEFT RIGHT
(min.)
[Default = blank (•) blank (•)]
See
Maximum Program
Time
table (below)
AC Fail
ADDRESS 0717
Report Delay
LEFT RIGHT
(min.)
[Default = 60 mins. = 3 C]
CHIME
ADDRESS 0716
TIMEOUT
LEFT RIGHT
(¼sec.)
[Default = 2 sec. = blank (•) 8]
ADDRESS LOC.
Program
LEFT RIGHT
Option
ENTER DATA
"
CHIME TIMEOUT OPTIONS
TIMEOUT
LEFT
RIGHT
blank (•) blank (•)
(0) ¼sec. = 0 sec.
blank (•)
2
(2) ¼sec. = ½ sec.
blank (•)
3
(3) ¼sec. = ¾ sec.
blank (•)
4
(4) ¼sec. = 1 sec.
blank (•)
5
(5) ¼sec. = 1.25 sec.
blank (•)
6
(6) ¼sec. = 1.5 sec.
blank (•)
7
(7) ¼sec. = 1.75 sec.
blank (•)
8
(8) ¼sec. = 2 sec.
F
F
(255) ¼sec. = 63.25
DATA ENTRIES
AC FAIL REPORT DELAY OPTIONS
TIMEOUT
LEFT
RIGHT
blank (•) blank (•)
blank (•)
blank (•)
1
1
blank (•)
2
2
blank (•)
3
3
blank (•)
4
4
blank (•)
5
5
blank (•)
6
6
blank (•)
7
7
F
F
255 min. = 4 Hr., 30 min.
DATA ENTRIES
DELAY/
LEFT
RIGHT TIMEOUT
blank (•) blank (•)
0 sec.
blank (•)
F
15 sec.
1
E
30 sec.
2
D
45 sec.
3
C
60 sec.
5
0
90 sec.
7
8
120 sec.
F
F
255 min.
DATA ENTRIES
Maximum Program Time
Address
Units
Max Prog Time
1179
VERSION 10 - MIN
VERSION 9A - SEC
VERSION 10 - 254 MIN
VERSION 9A - 254 SEC
PROGRAMMING TIMEOUTS:
Either use the tables provided or calculate your own timeout
using the steps indicated. WARNING:
Timers have uncertainty of +/-1sec, so a "time" of 1
second may actually timeout IMMEDIATELY.