GEM-P1632 Programming Instructions
!
Page 35
KEYPAD OPTIONS (ADDRESS 0723-0736 & 1055-1058)
K
e
yp
ad
Op
tio
n
s
*
NOTE:
Not for UL Installations.
KEYPAD OPTIONS:
Select options for any of the 7 keypads.
!
1. Select the desired option entering the option number (1-8) for each digit.
!
2. Enter corresponding option number in address location.
NOTE:
Dark shaded data value box shows option not available.
!
3. Press
U
or
D
to save.
[Default = blank (•) blank (•)]
[Default = blank (•) blank (•)]
[Default = blank (•) blank (•)]
[Default = blank (•) blank (•)]
[Default = blank (•) blank (•)]
[Default = blank (•) blank (•)]
KEYPAD TYPE:
Up to 7 keypads may be programmed, if they are connected.
NOTE:
See Keypad Configuration Mode. By default from the factory, each keypad is configured
as number 1.
!
1. Select keypad type for each keypad from the tables shown.
!
2. Enter in corresponding right and left digit address locations above.
!
3. Press
U
or
D
to save.
KEYPAD OPTIONS (ADDRESS 0723-0736)
RIGHT OPTION
blank (•) Disabled
1
Active
Keypad
KEYPAD
ASSIGNMENT
KEYPAD
NO.
KEYPAD OPTIONS
LEFT DATA VALUES (CIRCLE
"
)
ADDRESS 0730-0736
KEYPAD OPTIONS
RIGHT DATA VALUES (CIRCLE
"
)
RSRVD
PANEL
ACCESS
EASY
ARMING
AMBUSH LEFT
ADDR
RIGHT
RSRVD
KEYPAD
PANIC
KEYPAD
AUX. *
KEYPAD
FIRE
1
8
4
2
1
0730
8
4
2
1
2
8
4
2
1
0731
8
4
2
1
3
8
4
2
1
0732
8
4
2
1
4
8
4
2
1
0733
8
4
2
1
5
8
4
2
1
0734
8
4
2
1
6
8
4
2
1
0735
8
4
2
1
7
8
4
2
1
0736
[Default = blank (•) blank (•) from address 0730-0736] * NOTE: Keypad Aux. is not to be selected for UL Installations.
Keypad 1 Type
LEFT
RIGHT
ADDRESS 0723
Keypad 5 Type
LEFT
RIGHT
ADDRESS 0727
Keypad 2 Type
LEFT
RIGHT
ADDRESS 0724
Keypad 6 Type
LEFT
RIGHT
ADDRESS 0728
Keypad 3 Type
LEFT
RIGHT
ADDRESS 0725
Keypad 4 Type
LEFT
RIGHT
ADDRESS 0726
Keypad 7 Type
LEFT
RIGHT
ADDRESS 0729
LEFT
OPTION
blank
(•)
Burg Keypad
2
Wizard Keypad *
KEYPAD TYPE
[Default = blank (•) blank (•)]