GEM-P1632 Programming Instructions
L
NAPCO Security Systems
!
Page 22
The displays shown on the previous page will appear after a brief delay.
!
Use the the
A
button to toggle the cursor between the 4-digit address field and the data entry locations.
!
Enter the address directly using the number buttons.
!
The contents of the address will be read automatically, and the cursor will advance to the data field. Enter the
required data directly using the number buttons.
!
Press
J
to save the contents of each address.
PROGRAMMING OVERVIEW
The Keypad Programming Worksheets in the back are provided as an address-programming reference to help the
installer modify his custom default program or to make minor field alterations to an existing panel program. It is
recommended that the panel be uploaded to Napco's Quickloader software following any keypad programming and that
the PCD3000's error-check feature be utilized to reduce the possibility of programming omissions or conflicts.
Note: Most of the addresses shown comprise two data entry locations, left and right digits. Program the left digits on the
left data-display segment, and the right digit on the right segment. For those addresses having only one programmable
nibble, program the right segment only; the left segment should display a blank (•).
Keep the Keypad Programming Worksheets on file for future reference.
General Programming Steps
!
1. Contact the central station to ascertain receiver format, data format, event codes, subscriber numbers and
telephone number(s).
!
2. Select the desired features by circling
"
the respective “address” boxes. Refer to the Programming Options and
Worksheets for guidance in selecting the “data” (1,2,4,8) to be entered into those boxes.
!
3. Program the data entered in the boxes on the worksheets into the respective addresses. The display will show the
entry numerically, but will display “0” for the number 10, and letters “B”, “C”, “D”, “E”, and “F” for the numbers 11
through 15, respectively. To program a 10, press
G 0
. To program 11 through 15, press
G 1
through
G 5
, respectively.
NOTE:
See the Direct Address Programming Example on the following page.
EXIT DIRECT ADDRESS PROGRAM MODE:
When done, press the
C
button to exit and resume normal keypad
operation. The panel is now programmed with your program.
ENTRY
TOTAL
PRESS
N
KEYPAD
DISPLAYS
8
4
2
1
blank
0
•
8
4
2
!
1
1
1
8
4
"
1
2
2
2
8
4
"
!
3
3
3
8
#
2
1
4
4
4
8
#
2
!
5
5
5
8
#
"
1
6
6
6
8
#
"
!
7
7
7
$
4
2
1
8
8
8
$
4
2
!
9
9
9
$
4
"
1
10
G 0
0
$
4
"
!
11
G 1
B
$
#
2
1
12
G 2
C
$
#
2
!
13
G 3
D
$
#
"
1
14
G 4
E
$
#
"
!
15
G 5
F
DATA ENTRY SELECTIONS
(BINARY VALUE CIRCLED)
"
Table 1. Determining data entry for a location (each
“nibble”). Numbers in parentheses indicate data for
selected zones or features. (See Programming
Worksheets that follow.)
B. GEM-K3DGTL/GEM-RP3DGTL Keypads
To access Direct Address Program
Mode, press
C
in the Easy
Menu Mode.
1. Press
R
.
2. Enter the 4 digit Address location
directly using number buttons
(0-9).
3. Enter the 2 digit data directly
using number buttons (0-9).
4. Press
U
to save.
To exit, press
C
.
NOTE:
“A” =
G
0
; “B” =
G
1
; “C” =
G
2
; “D” =
G
3
; “E” =
G
4
;
“F” =
G
5
. Press
0
for a zero or to clear.
Di
rec
t
A
d
dre
ss
P
rogr
am Mode
Example: GEM-RP2ASe2 / GEM-RP3DGTL / GEM-RP4RFC--Direct Address Programming
Program Zones 6, 7 and 8 as Exit/Entry Follower Zones.
DETERMINE THE DATA ENTRIES
!
1. Referring to ZONE FEATURES in the Programming Worksheets that follow, Exit/Entry Follower for Zones 5
through 8 are located at address 0506, left digit. Circle
"
the data values for Zones 5–8.
!
2. Add the data values for Zones 6, 7 and 8: 2+4+8=14. From Tables 1 and 2, “14” (E) is entered as press
G4
. The right digit (for Zones 1 through 4, none of which are Exit/Entry Follower Zones) is entered as
a blank (•).
PROGRAM THE DATA ENTRIES
1. Enter the panel's Dealer Security Code (Address 0500), then press
R
.
2. Answer NO (
F
) to all questions until “
ACTIVATE PROGRAM Y/N
” is displayed; then press the NEXT/YES button.
NOTE:
If you pass “
ACTIVATE PROGRAM
”, scroll backward using
B
.
3. Press
C
to enter the Address Program Mode. Address "
0000
" will display.
4. Press
0506
to access Address 0506.
The data for both digits will display and the cursor will
advance to the data field.
5. Press
G
4
to enter an “E” in the left digit and press
0
to enter a blank (•) in the right digit.
6. Press
U
to save. Address 0506 is now programmed with “E •”.
7. Enter another 4-digit address to continue programming or press
C
to exit and resume normal keypad operation.
ZONE OPTION
ZONES
LEFT DATA VALUES
SUM = 14 (CIRCLE
"
)
ADDRESS 0506
ZN08
ZN07
ZN06 ZN05
L
ADDR
R
ZN04
ZN03
ZN02 ZN01
EXIT/ENTRY FOLLOWER
$
#
"
1
E
0506 BLANK (•)
8
4
2
1
ZONES
RIGHT DATA VALUES
SUM = 0 (CIRCLE
"
)
ENTER DATA
"
Flashing
R
COMPUTERIZED SECURITY SYSTEM
ARMED
STATUS
SYSTEM ARMED
01/01/97 12:00AM
1 2
4
3
5 6
7 8 9 0
A
B
C
D
E
F
G
NEXT/YES
PRIOR/NO
AREA
GEMINI
ENT A1
3C
INTERIOR
BYPASS
FIRE/TBL
SYS TBL
CHIME
Press here to
Select NEXT/
PRIOR address