L
NAPCO Security Systems
X
GEM-P1632 Programming Instructions
!
Page 3
SYSTEM PROGRAMMING OPTIONS ...................................................4
Introduction .......................................................................................4
Downloading From a Computer ........................................................4
EASY MENU DRIVEN PROGRAM MODE .............................................5
Dealer Program - Preliminary Information ........................................5
Accessing Dealer Program Mode .....................................................5
Customizing a Default Program ........................................................5
GEM-RP2ASe2/GEM-K2AS KEYPAD Easy Program Menu .....6
Total Number of Zones in Area 1 ..........................................6
Panel Zone Doubling .............................................................6
Fire Zones in Area 1 ..............................................................6
2-Wire Fire Zones in Area 1 ..................................................6
Local or Central Station Reporting System ...........................6
Exit/Entry Zones in Area 1 .....................................................6
Interior (Stay) Bypass Zones in Area 1 .................................7
24 Hour Zones in Area 1 ......................................................7
Chime Zones in Area 1 .........................................................7
Chime 2 Zones in Area 1 ......................................................7
Exit/Entry2 Zones in Area 1 ..................................................7
50 mS Loop Response Zones ..............................................7
Aux Output Activated on Alarm Zones .................................7
Sensor Watch Zones ............................................................7
Keypad Sounder On Alarm Zones .......................................7
Auto Bypass Re-entry Zones ................................................8
Enable No EOLR Zones ........................................................8
Enable Telco Line Fault Test? ...............................................8
Enable Burg Output Chirp on KeyFob? .................................8
Enable CP1? .........................................................................8
Number of Keypads in Area 1 ...............................................8
Central Station Receiver 1 Tel. Number ................................8
Central Station Receiver 1 Account Number .........................9
Central Station Receiver 1 Format ........................................9
Enter User Codes ..................................................................9
RF Transmitter Points ...........................................................10
Key Fob Transmitters ............................................................11
Enter Zone Descriptions ........................................................11
Dealer Code ..........................................................................11
Clear Program .......................................................................12
Cold Start ..............................................................................12
GEM-RP3DGTL/GEM-K3DGTL and GEM-RP4RFC/GEM-K4RF
KEYPAD Easy Program Menu ..................................................13
Total Number of Zones in Area 1 ..........................................13
Panel Zone Doubling ............................................................13
Fire Zones .............................................................................13
2-Wire Fire Zones ..................................................................13
Local or Central Station Reporting System ...........................13
Exit/Entry Zones ....................................................................13
Interior Zones ........................................................................14
24 Hour Zones in Area 1 ......................................................14
Chime Zones in Area 1 .........................................................14
Chime 2 Zones in Area 1 ......................................................14
Exit/Entry2 Zones in Area 1 ..................................................14
50 mS Loop Response Zones ..............................................14
Aux Output Activated on Alarm Zones .................................14
Sensor Watch Zones ............................................................15
Keypad Sounder On Alarm Zones .......................................15
Auto Bypass Re-entry Zones ...............................................15
Enable No EOLR Zones .......................................................15
Enable Telco Line Fault Test? ...............................................15
Enable Burg Output Chirp on KeyFob? .................................15
Enable CP-01? ..................................................................... 15
Number of Keypads .............................................................. 16
Central Station Receiver 1 Tel. Number ............................... 16
Central Station Receiver 1 Account Number ........................ 16
Central Station Receiver 1 Format ....................................... 16
Enter User Codes ................................................................. 16
RF Transmitter Points ........................................................... 17
Key Fob Transmitters ........................................................... 18
Key Fob Transmitters as Zone Input Devices ...................... 18
Dealer Code .......................................................................... 18
Clear Program ...................................................................... 18
DIRECT ADDRESS PROGRAM MODE ................................................. 20
Keypad Programming Overview ....................................................... 20
Accessing Direct Address Program Mode ........................................ 20
Keypad Address Program Mode Display .......................................... 21
Direct Address Program Mode Keypad Commands ......................... 21
Direct Address Programming Example ............................................ 22
Conventions Used in this Manual ..................................................... 23
System Delays & Timeouts (Addr 0000-0002, 0711,
0715, 1059 & 1179) .................................................................... 24
System Delays & Timeouts (Addr 0716-0717) ................................. 24
System Output Timeouts (Addr 0710, 0712-0714) ........................... 25
Download/Callback Opt. (Addr 1183, 0236-0255) ............................ 25
Pager Format Options (Addr 0256 & 0257) ...................................... 25
Syst. Opt. & Ambush Code (Addr 0460-0485 & 1054) ..................... 26
System Options (Addr 0718-0722) ................................................... 27
System Options (Addr 1060-1062) ................................................... 28
CS Receiver Opt. (Addr 0170-0235) ................................................ 29
CS Subscriber Reporting Opt. (Addr 0259-0350) ............................. 30
CS Zn Reporting Opt. (Addr 0358-0389 & 0391-0394) .................... 31
CS User Reporting Opt. (Addr 0440-0459) ...................................... 32
EZM Group & Area Arming Opt. (Addr 0737-0744) .......................... 33
Area Bell Control Options (Addr 0745-0749) .................................... 34
Keypad Options (Addr 0723-0736) ................................................... 35
Zones 1-16 Options (Addr 0490-0595) ............................................. 36
Zones 17-32 Options (Addr 0601-0705) ........................................... 37
External Relay Control (Addr 0750-0829) ........................................ 38
RF Rcvrs. & Sup. Timers (Addr 1038-1053 & 1180) ........................ 40
Clear Program Options (Addr 1197 & 1198) .................................... 41
USER PROGRAM MODE ....................................................................... 41
Preliminary Information ..................................................................... 41
Accessing User Program Mode ........................................................ 42
User Codes ....................................................................................... 42
KEYPAD CONFIGURATION MODE ...................................................... 43
Keypad Installation ........................................................................... 43
Configuring the Keypads .................................................................. 43
ALPHABETICAL INDEX ........................................................................ 44
ADDRESS NUMBER LOCATION INDEX .............................................. 47
GEM-P1632 WIRING DIAGRAM ............................................................ 52
TABLE OF CONTENTS
Refer to accompanying GEM-P1632 Installation Instructions (WI808) for installation information.
NOTE: THESE PROGRAMMING INSTRUCTIONS ARE INTENDED AND WRITTEN FOR THE PROFESSIONAL INSTALLER HAVING SUITABLE
EXPERIENCE AND INSTALLATION EQUIPMENT. THE UNIT IS DESIGNED TO BE PROGRAMMED USING AN IBM-COMPATIBLE
COMPUTER WITH NAPCO PCD3000 SOFTWARE. AFTER PROGRAMMING, BE SURE TO RUN THE PCD3000 ERROR-CHECK UTILITY TO
GUARD AGAINST PROGRAMMING CONFLICTS FOR THE TYPE OF SERVICE SELECTED FOR THE INSTALLATION.