X
GEM-P1632 Programming Instructions
L
NAPCO Security Systems
!
Page 8
GEM-RP2
A
Se2
/GEM-K2
A
S
--Ea
s
y
Me
nu Dr
iv
en Pr
o
g
ram Mode
Auto Bypass Re-entry Zones
(New Program Only)
(Not evaluated by UL)
•
Enter the zone numbers of zones to be Auto Bypass Re-entry zones.
•
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
•
Press
U
to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
•
Auto Bypass Re-entry Zones allow the system to be armed with the zone faulted but come back into the
system (armed) when the zone is subsequently secured.
Enable No EOLR Zones
(New Program Only)
•
Press the NEXT/YES button to program all zones except 24 Hr & fire zones for No End Of Line Resis-
tor. Press the PRIOR/NO button to continue.
•
Do not program this feature for UL Installations.
Enable Telco Line Fault Test?
(New Program Only)
•
Press the NEXT/YES button to enable Telco Line Fault Test.
•
Press the PRIOR/NO button to continue.
NOTE:
If enabled, a Telco Line Fault Test Delay of 60 seconds will automatically be programmed.
Enable Burg Output Chirp on KeyFob?
(New Program Only)
•
Press the NEXT/YES button to enable Burg Output Chirp on KeyFob Arm / Disarm.
•
Press the PRIOR/NO button to continue.
NOTE:
The Burg Output will chirp once on Keyfob Arm and twice on Keyfob Disarm.
Enable SIA CP1?
(New Program Only)
•
Press the NEXT/YES button to enable.
•
Press the PRIOR/NO button to continue.
The SIA CP-01 Features are designed to reduce the incidence of false alarms. See WI808, "Installer Program-
ming Quick Reference Chart SIA False Alarm Reduction" and "GEM-P1632 Factory Default Description" for
more information.
NOTE:
Do not enable unless reporting, otherwise system trouble
Fail to Communicate
may occur.
Number of Keypads in Area 1
Directly enter the total number of Keypads to be installed in Area 1. Valid entries are from 01 to 07. Directly
enter the number of keypads, including leading zeros. Use number buttons
1
through
9
.
NOTE:
Press
0
for a zero. Press
U
to save. Press the NEXT/YES button to proceed.
NOTE:
Area 2 keypads
can only be assigned in Direct Address Programming. See Keypad Options.
Central Station Receiver 1 Telephone Number
Using number buttons, enter telephone number of up to 16 digits including prefix letters, if necessary, for
receiver 1. Use number buttons
1
through
9
for digits 1–9; press the
G
0
buttons for a zero
and
G
1
through
G
5
for letters B–F, respectively.
NOTE:
Pre-Dial Delay = “D”; Dial-Tone
Detection = “E”. Pressing
0
will produce a blank space (•). Press
U
to save. Press the NEXT/YES but-
ton to proceed.
NOTE:
Central Station Receiver 2 and 3 Telephone Numbers can only be entered in Direct Address
Programming. See CS Receiver Options.
(Press YES or NO)
E n N E O L
Y / N
(Direct Entry)
E n t A U B
Z n # X X
(Press YES or NO)
T e l c o
L n F i t
Y / N
(Press YES or NO)
K F O u t
C h i r p
Y / N
(Press YES or NO)
E n a b l e
C P 0 1 ?
Y / N
(Direct Entry)
E n t A 1
# K P 0 1
(Direct Entry)
P h o n e #
_ _ _ _ _ _
_ _ _ _ _ _