Address
Name of system register
Default
value
Set value (parameter)
Allocation
of user
memory
0
Sequence program area
capacity
The set values are fixed and cannot be
changed.
The stored values vary depending on the
model and type.
K3: 3 K words (FP0 C10, C14, C16)
K5: 5 K words (FP0 C32)
1 to 3
Unused
Hold/
Non–
hold
5
Timer and counter division
(setting of leading counter
number)
K100
K0 to K144
For detailed information,
hold
6 to 8
Unused
With the FP0, values set with the program-
ming tool become invalid.
9 to 13
Unused
14
Unused
With the FP0, values set with the program-
ming tool become invalid.
15
Unused
Action on
error
20
Disable or enable setting for
duplicated output
K0
K0: Disable (will be syntax error)
K1: Enable (will not be syntax error)
21, 22
Unused
23
Operation setting when an I/O
verification error occurs
K0
K0: Stop
K1: Continuation
24, 25
Unused
26
Operation setting when an
operation error occurs
K0
K0: Stop
K1: Continuation
27 to 29
Unused
4
Unused
With the FP0, values set with the program-
ming tool become invalid.
Содержание FP Series
Страница 12: ...Chapter 1 Overview...
Страница 21: ...FP0 Hardware Overview 1 10 Matsushita Electric Works Europe AG...
Страница 22: ...Chapter 2 Control Units...
Страница 44: ...Chapter 3 Expansion I O Units...
Страница 67: ...FP0 Hardware Expansion I O Units 3 24 Matsushita Electric Works Europe AG...
Страница 68: ...Chapter 4 Analog I O Unit...
Страница 87: ...FP0 Hardware Analog I O Unit 4 20 Matsushita Electric Works Europe AG...
Страница 88: ...Chapter 5 FP0 I O Link Unit MEWNET F...
Страница 102: ...Chapter 6 Power Supply Unit...
Страница 105: ...FP0 Hardware Power Supply Unit 6 4 Matsushita Electric Works Europe AG...
Страница 106: ...Chapter 7 I O Allocation...
Страница 112: ...Chapter 8 Installation...
Страница 122: ...Chapter 9 Wiring...
Страница 139: ...FP0 Hardware Wiring 9 18 Matsushita Electric Works Europe AG...
Страница 140: ...Chapter 10 Trial Operation...
Страница 143: ...FP0 Hardware Trial Operation 10 4 Matsushita Electric Works Europe AG...
Страница 144: ...Chapter 11 Self Diagnostic and Troubleshooting...
Страница 156: ...Appendix A System Registers...
Страница 170: ...Appendix B Special Internal Relays...
Страница 174: ...Appendix C Special Data Registers...
Страница 183: ...FP0 Hardware Special Data Registers C 10 Matsushita Electric Works Europe AG...
Страница 184: ...Appendix D Dimensions...
Страница 195: ...FP0 Hardware Dimensions D 12 Matsushita Electric Works Europe AG...