Users Guide Viper Extreme
CHAPTER 5: Printer menu
77
AP-75330 Rev. 1.0 14/01/09
5.4.1.11 Heater menu
Notes
The default heater setting is set to 50°C.
The function of the heater (A): Warming the transfer media before entering the pressure rollers. The
pre-expansion helps to minimize media cockling.
We recommend setting the pre-heater temperature at 50°C. This to expand the transfer media before
reaching the pressure rollers.
5.4.1.12 Drier menu
Notes
The default drier setting is set to 50°C.
The function of the drier (D): Heating the printed transfer media evaporates the water fast enough so
that the print is touch-dry when wound.
5.4.1.13 HStatus menu
Check the temperature of the heating elements.
Notes
A stands for the Heater.
D stands for the Dryer.
Press the [CANCEL] key to go to the previous menu.
Содержание Viper Extreme
Страница 2: ...User s Guide Viper Extreme 2 AP 75330 Rev 1 0 14 01 09 This page is intentionally left blank ...
Страница 4: ...User s Guide Viper Extreme 4 AP 75330 Rev 1 0 14 01 09 This page is intentionally left blank ...
Страница 6: ...User s Guide Viper Extreme 6 AP 75330 Rev 1 0 14 01 09 This page is intentionally left blank ...
Страница 40: ...User s Guide Viper Extreme CHAPTER 3 Basics 40 AP 75330 Rev 1 0 14 01 09 This page is intentionally left blank ...