Users Guide Viper Extreme
CHAPTER 2 Product overview
21
AP-75330 Rev. 1.0 14/01/09
2.3 INSTALLATION REQUIREMENTS
2.3.1 Installation environment requirements
Choose a place for printer installation following the requirements in the table below.
Area
65 model
12.7m² (144ft²) or larger. Frontage of 4.7m (15.7ft) or greater.
90 model
14.3m² (162ft²) or larger. Frontage of 5.3m (17.7ft) or greater.
Floor loading capability
2940 Pa (300kg/m²) or over
Electrical
Voltage
AC 100-120V
AC 220-240V
Frequency
60/50Hz±1Hz
Capacity
AC100V-120V : 12A
AC220V-240V : 6A
In order to protect the printer for over currents, short circuits and earth faults, equip the building
installation with an automatic breaker double pole of 20 A and an earth leakage switch of 300 mA.
Environmental
Recommended
working
environment
Temperature: 25°
Humidity: 30% to 60%, without condensation
Operational
conditions
Temperature: 19° to 26°
Humidity: 30% to 60%, without condensation
Rate of change
Temperature: No more than 2° per hour
Humidity: No more than 5% per hour
Storage
environment
Temperature: -20° to 60°
Humidity: 5
to 85%, without condensation (When ink has been
discharged.)
2.3.2 Required space
Install the product on a flat surface that fulfils the following conditions.
a
= 1,5 m
b
= 1,5 m
c
= 2,5 m
d
= 0,6 m
e
= 1,3 m
Содержание Viper Extreme
Страница 2: ...User s Guide Viper Extreme 2 AP 75330 Rev 1 0 14 01 09 This page is intentionally left blank ...
Страница 4: ...User s Guide Viper Extreme 4 AP 75330 Rev 1 0 14 01 09 This page is intentionally left blank ...
Страница 6: ...User s Guide Viper Extreme 6 AP 75330 Rev 1 0 14 01 09 This page is intentionally left blank ...
Страница 40: ...User s Guide Viper Extreme CHAPTER 3 Basics 40 AP 75330 Rev 1 0 14 01 09 This page is intentionally left blank ...