Procedure
Illustration
3) Remove the hex nuts and washers securing
the compressor, located on the bottom
plate (see CJ_ODU_COMP_003).
4) Heat up the brazed parts and then remove
the the discharge pipe and the suction
pipe (see CJ_ODU_COMP_004).
5) Lift the compressor from the base pan
assembly with pliers.
CJ_ODU_COMP_003
CJ_ODU_COMP_004
Note: This section is for reference only. Actual unit appearance may vary.
Discharge Pipe
Suction Pipe
Service manual
H11 series
e
Outdoor Unit Disassembly 37
f
Содержание MUPR-09-H11-E
Страница 1: ...Service manual MUPR H11 www mundoclima com CL20055 CL20058 R32...
Страница 16: ...Service manual H11 series MUPR 24 H11 I Specifications 7f e...
Страница 17: ...Outdoor unit wiring diagram 16022000019533 Service manual H11 series MUPR 09 12 18 H11 E Specifications 8 f e...
Страница 18: ...Service manual H11 series MUPR 24 H11 E Specifications 9 f e...
Страница 58: ...e Outdoor Unit Disassembly 3 f 1 Panel Plate X101 Service manual H11 series MUPR 09 12 H11 E 2 Dimension...
Страница 59: ...e Outdoor Unit Disassembly 4 f 2 Panel Plate X301 Service manual H11 series MUPR 18 H11 E...
Страница 60: ...e Outdoor Unit Disassembly 5 f 3 Panel Plate X401 Service manual H11 series MUPR 24 H11 E...
Страница 117: ...Service manual H11 series e f Troubleshooting 25...