![mundoclima MUPR-09-H11-E Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/mundoclima/mupr-09-h11-e/mupr-09-h11-e_service-manual_1856741078.webp)
e
Outdoor Unit Disassembly 23
f
Procedure
Illustration
5) Pull out the wire connected with the
terminal. (see
CJ_ODU_PCB_007-4
).
6) Pull out connectors of the condenser
coil temp. sensor(T3),outdoor ambient
temp. sensor(T4) and discharge temp.
sensor(TP) (see
CJ_ODU_PCB_007-4
).
7) Disconnect the electronic expansion
valve wire (see Fig
CJ_ODU_PCB_007-
4
).
8) Remove the connector for 4-way valve.
(see Fig
CJ_ODU_PCB_007-4
).
9) Remove the connector for the reactor
(see Fig
CJ_ODU_PCB_007-4
).
10) Then remove the electronic control box
(see Fig
CJ_ODU_PCB_007-4
).
CJ_ODU_PCB_007-4
Note: This section is for reference only. Actual unit appearance may vary.
4-Way Valve
Reactor
T3/T4
TP
Terminal
Service manual
H11 series
Содержание MUPR-09-H11-E
Страница 1: ...Service manual MUPR H11 www mundoclima com CL20055 CL20058 R32...
Страница 16: ...Service manual H11 series MUPR 24 H11 I Specifications 7f e...
Страница 17: ...Outdoor unit wiring diagram 16022000019533 Service manual H11 series MUPR 09 12 18 H11 E Specifications 8 f e...
Страница 18: ...Service manual H11 series MUPR 24 H11 E Specifications 9 f e...
Страница 58: ...e Outdoor Unit Disassembly 3 f 1 Panel Plate X101 Service manual H11 series MUPR 09 12 H11 E 2 Dimension...
Страница 59: ...e Outdoor Unit Disassembly 4 f 2 Panel Plate X301 Service manual H11 series MUPR 18 H11 E...
Страница 60: ...e Outdoor Unit Disassembly 5 f 3 Panel Plate X401 Service manual H11 series MUPR 24 H11 E...
Страница 117: ...Service manual H11 series e f Troubleshooting 25...