e
f
2.
2.1
When the indoor unit encounters a recognized error on different models ,
1. the running LED with flash in a corresponding series, the timer LED may turn on or begin flashing;
2. an error code will be displayed;
3. both 1 and 2.
These error codes are described in the following tables:
Running
Lamp
Timer
Lamp
Display
Information
Solution
--
--
F
Defrost
Normal
Display
, not
error code
--
--
CL
Filter cleaning reminder(power on display for 15 seconds)
--
--
CL
Active clean
--
--
F
Filter replacement reminder(power on display for 15 seconds)
--
--
FP
Heating in room temperature under 8°C
--
--
FC
Forced cooling
--
--
AP
AP mode of WIFI connection
--
--
CP
Remote switched off
1 time
OFF
EH 00/EH 0A
Indoor unit EEPROM parameter error
TS01-IDU
2 times
OFF
EL 01
Indoor/outdoor unit communication error
TS02-S-INV
3 times
OFF
EH 02
Zero-crossing signal detection error
TS03
4 times
OFF
EH 03
The indoor fan speed is operating outside of the normal range
TS04-S-IDU
5 times
OFF
EC 51
Outdoor unit EEPROM parameter error
TS01-ODU
5 times
OFF
EC 52
Condenser coil temperature sensor T3 is in open circuit or has short
circuited
TS05-ODU
5 times
OFF
EC 53
Outdoor room temperature sensor T4 is in open circuit or has short
circuited
TS05-ODU
5 times
OFF
EC 54
Compressor discharge temperature sensor TP is in open circuit or
has short circuited
TS05-ODU
5 times
OFF
EC 56
Evaporator coil outlet temperature sensor T2B is in open circuit or
has short circuited(for free-match indoor units)
TS05-ODU
6 times
OFF
EH 60
Indoor room temperature sensor T1 is in open circuit or has short
circuited
TS05-IDU
6 times
OFF
EH 61
Evaporator coil middle temperature sensor T2 is in open circuit or
has short circuited
TS05-IDU
12 times
OFF
EC 07
The outdoor fan speed is operating outside of the normal range
TS04-ODU
9 times
OFF
EH 0
Indoor PCB/Display board communication error
TS07
8 times
OFF
EL 0C
Refrigerant leakage detection
TS06-INV
7 times
FLASH
PC 00
IPM malfunction or IGBT over-strong current protection
TS09-S
2 times
FLASH
PC 01
Over voltage or over low voltage protection
TS10-S
Service manual
H11 series
Troubleshooting 3
Содержание MUPR-09-H11-E
Страница 1: ...Service manual MUPR H11 www mundoclima com CL20055 CL20058 R32...
Страница 16: ...Service manual H11 series MUPR 24 H11 I Specifications 7f e...
Страница 17: ...Outdoor unit wiring diagram 16022000019533 Service manual H11 series MUPR 09 12 18 H11 E Specifications 8 f e...
Страница 18: ...Service manual H11 series MUPR 24 H11 E Specifications 9 f e...
Страница 58: ...e Outdoor Unit Disassembly 3 f 1 Panel Plate X101 Service manual H11 series MUPR 09 12 H11 E 2 Dimension...
Страница 59: ...e Outdoor Unit Disassembly 4 f 2 Panel Plate X301 Service manual H11 series MUPR 18 H11 E...
Страница 60: ...e Outdoor Unit Disassembly 5 f 3 Panel Plate X401 Service manual H11 series MUPR 24 H11 E...
Страница 117: ...Service manual H11 series e f Troubleshooting 25...