e
Troubleshooting 10
f
PC 06
Compressor discharge temperature protection
PC 08
Outdoor current protection
PH 09
Anti-cold air in heating mode
PC 0F
PFC module malfunction
pc 0l
Outdoor ambient tempreture too low
PH 90
Evaporator coil temperature over high protection
PH 91
Evaporator coil temperature over low Protection
LC 05
Frequency limit caused by voltage
LC 03
Frequency limit caused by current
LC 02
Frequency limit caused by TP
LC 01
Frequency limit caused by T3
LH 00
Frequency limit caused by T2
LC 06
Frequency limit caused by PFC
LH 07
Frequency limit caused by remote controller
nA
no malfuction or pretecion
Service manual
H11 series
Содержание MUPR-09-H11-E
Страница 1: ...Service manual MUPR H11 www mundoclima com CL20055 CL20058 R32...
Страница 16: ...Service manual H11 series MUPR 24 H11 I Specifications 7f e...
Страница 17: ...Outdoor unit wiring diagram 16022000019533 Service manual H11 series MUPR 09 12 18 H11 E Specifications 8 f e...
Страница 18: ...Service manual H11 series MUPR 24 H11 E Specifications 9 f e...
Страница 58: ...e Outdoor Unit Disassembly 3 f 1 Panel Plate X101 Service manual H11 series MUPR 09 12 H11 E 2 Dimension...
Страница 59: ...e Outdoor Unit Disassembly 4 f 2 Panel Plate X301 Service manual H11 series MUPR 18 H11 E...
Страница 60: ...e Outdoor Unit Disassembly 5 f 3 Panel Plate X401 Service manual H11 series MUPR 24 H11 E...
Страница 117: ...Service manual H11 series e f Troubleshooting 25...