TS14: Indoor units mode conflict (match with multi outdoor unit)
Description:
The indoor units cannot work cooling mode and heating at same time. Heating mode has a priority.
• Suppose Indoor unit A working in cooling mode or fan mode, and indoor unit B is set to heating mode, then A will
change to off and B will work in heating mode.
• Suppose Indoor unit A working in heating mode, and indoor unit B is set to cooling mode or fan mode, then B will
change to stand by and A will be no change.
Cooling mode
Heating Mode
Fan
Off
Cooling mode
No
Yes
No
No
Heating Mode
Yes
No
Yes
No
Fan
No
Yes
No
No
Off
No
No
No
No
Note:
No
: No mode conflict
Yes
: Mode conflict
Service manual
H11 series
e
f
Troubleshooting 43