1.4520.582 – MIC5 IPE Primary Open Cylinder 13
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 13 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.583 – MIC5 IPE Primary Open Cylinder 14
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 14 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.584 – MIC5 IPE Primary Open Cylinder 15
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 15 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.585 – MIC5 IPE Primary Open Cylinder 16
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 16 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.586 – MIC5 IPE Primary Open Cylinder 17
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 17 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.587 – MIC5 IPE Primary Open Cylinder 18
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 18 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.588 – MIC5 IPE Primary Open Cylinder 19
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 19 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.