1.4520.560 – MIC5 E1 Tr1 index too early / faulty
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
The index mark of trigger 1
(B1.2) was detected too early or
was faulty.
u
Check sensor, sensor spacing, cabling, settings in data record
and timing wheel. Replace sensor if required.
1.4520.561 – MIC5 E1 Tr1 index too late / missing
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
The index mark of trigger 1
(B1.2) was detected too late or
was missing.
u
Check sensor, sensor spacing, cabling, settings in data record
and timing wheel. Replace sensor if required.
1.4520.570 – MIC5 IPE Primary Open Cylinder 1
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 1 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.571 – MIC5 IPE Primary Open Cylinder 2
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 2 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.572 – MIC5 IPE Primary Open Cylinder 3
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 3 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.573 – MIC5 IPE Primary Open Cylinder 4
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 4 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.574 – MIC5 IPE Primary Open Cylinder 5
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 5 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
MS15027/00E 2013-10
| Troubleshooting | 81