511 – HIHI P-Charge Mix A
Red alarm. Engine stop.
Associated parameter 2.0181.932
Cause
Corrective action
Mixture pressure on A side too
high (limit value 2).
1. Check emissions.
2. Check ignition timing (→ Page 160).
3. Check exhaust back pressure.
4. Check valve clearance (→ Page 165).
5. Check throttle.
6. Check mixture coolant system.
512 – HIHI P-Charge Mix B
Red alarm. Engine stop.
Associated parameter 2.0182.932
Cause
Corrective action
Mixture pressure on B side too
high (limit value 2).
1. Check emissions.
2. Check ignition timing (→ Page 160).
3. Check exhaust back pressure.
4. Check valve clearance (→ Page 165).
5. Check throttle.
6. Check mixture coolant system.
513 – SD P-Coolant Diff
Red alarm.
Associated parameter 1.8004.610
Cause
Corrective action
Coolant differential pressure
sensor defective, short circuit or
wire break.
u
Check sensors and cabling (B16.1, B16.3), replace if necessary.
Fault is rectified following engine restart.
515 – AL Starter Not Engaged
Yellow alarm.
Associated parameter 1.8004.123
Cause
Corrective action
Gas temperature sensor
defective, short circuit or wire
break.
1. Not available in all engine versions (optional).
2. Check sensor and cabling (B38), replace as necessary.
517 – SD P-Charge Mix before Throttle
Red alarm.
Associated parameter 1.8004.631
Cause
Corrective action
Mixture pressure sensor before
throttle defective, short circuit
or wire break.
u
Check sensor and cabling (B79.23), replace if necessary. Fault
is rectified following engine restart.
MS15027/00E 2013-10
| Troubleshooting | 129
TIM-ID: 0000044567 - 001