554 – AL Ignition Fault
Red alarm.
Associated parameter 2.1090.122
Cause
Corrective action
Ignition failure. Alarm is
activated if the feedback signal
from ignition system is not
received within a specified time-
out period. Either the ignition
could not be activated, the time-
out period is set too short, or
communication is faulty.
1. Check ignition system.
2. Check cabling.
556 – AL GasValve Fault
Red alarm.
Associated parameter 2.1090.124
Cause
Corrective action
Gas supply solenoid valve faulty.
Alarm is activated when
problems with the gas supply
solenoid valves occur. Either the
gas supply solenoid valves are
faulty, the time-out period is set
too short, or communication is
faulty.
1. Check gas train.
2. Check cabling.
557 – AL speed drop fault
Red alarm. Engine stop.
Associated parameter 2.1090.126
Cause
Corrective action
Speed drop. Alarm is activated if
engine speed drops during
starting sequence.
u
Check gas train.
559 – AL mixture throttle A fault
Red alarm. Engine stop.
Associated parameter 1.1450.010
Cause
Corrective action
A problem related to mixture
throttle on A side occurred.
Possible causes: Mixture throttle
defective, no power supply to
throttle, cabling of feedback
and/or position signal faulty.
u
Check mixture throttle on A side and cabling. Replace mixture
throttle on A side if necessary.