451 – HI T-Charge Mix
Yellow alarm.
Associated parameter 2.0169.931
Cause
Corrective action
Mixture temperature is too high
(limit value 1). Mixture coolant
pump failure, volumetric flow
too low, cooling system inlet
temperature too high, mixture
cooler clogged.
1. Check mixture cooling circuit.
2. Check mixture cooler for dirt.
452 – HIHI T-Charge Mix
Red alarm. Engine stop.
Associated parameter 2.0169.932
Cause
Corrective action
Mixture temperature too high
(limit value 2). Mixture coolant
pump failure, volumetric flow
too low, cooling system inlet
temperature too high, mixture
cooler clogged.
1. Check mixture cooling circuit.
2. Check mixture cooler for dirt.
453 – LO T-Charge Mix
Yellow alarm.
Associated parameter 2.0169.921
Cause
Corrective action
Mixture temperature is too low
(limit value 3).
1. Check intake air temperature.
2. Check mixture cooling circuit.
454 – SS Power Reduction Active
Yellow alarm.
Associated parameter 2.7000.011
Cause
Corrective action
Power reduction activated.
u
Rectify limit value violation of the source alarm (e.g. reduce
intake air temperature).
457 – LO T-Intake Air
Yellow alarm.
Associated parameter 2.0123.921
Cause
Corrective action
Intake air temperature is too low
(limit value 3).
u
Check ventilation system.
126 | Troubleshooting | MS15027/00E 2013-10
TIM-ID: 0000044567 - 001