1.4520.575 – MIC5 IPE Primary Open Cylinder 6
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 6 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.576 – MIC5 IPE Primary Open Cylinder 7
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 7 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.577 – MIC5 IPE Primary Open Cylinder 8
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 8 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.578 – MIC5 IPE Primary Open Cylinder 9
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 9 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.579 – MIC5 IPE Primary Open Cylinder 10
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 10 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.580 – MIC5 IPE Primary Open Cylinder 11
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 11 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.581 – MIC5 IPE Primary Open Cylinder 12
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 12 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
82 | Troubleshooting | MS15027/00E 2013-10
TIM-ID: 0000044566 - 001