2.6.3 Retrofit Cross Duct Mounting Plate
The 180mm x 180mm retrofit mounting plate is capable of being mounted on the same mounting
holes as an earlier generation of Cross Duct unit supplied by another manufacturer. There is a
reasonable likelihood that mounting Cross Duct ELDS units on ducts using the retrofit mounting
plate will cause bending of the duct wall. Consequently, this method of mounting Cross Duct ELDS
units should only be considered for retrofit applications where it is impossible or impractical to
engineer a superior mounting arrangement. In such circumstances, the installation Design
Authority should also consider local reinforcement / bracing of the duct wall to reduce bending;
and / or the use of alignment adjustment bushings* to provide compensation for such bending.
NB:
Customer / user should retain the original installation’s internal plates - to which this retrofit
mounting plate will be attached.
The installation Design Authority is responsible for ensuring that the method chosen for
mounting Cross Duct ELDS units on the intended duct is sufficiently rigid and stable.
* Alignment adjustment bushings are available from Senscient (Part Number A-5126-0) for use
with Cross Duct ELDS systems where the duct walls are highly out-of-parallel, or have bent under
load by an amount greater than the angular tolerance of the Cross Duct ELDS system. Provided
that the angular errors arising from these sources are less than ±5° (per side) and the duct wall
deformation is relatively stable, the alignment adjustment bushings should be capable of returning
the alignment of Cross Duct ELDS systems to within their operational angular tolerance.
(
NB:
Alignment adjustment of ELDS VZ units is made possible by use of the standard Adjustable
Mounting Bracket.)
Содержание Senscient ELDS 1000 series
Страница 1: ...Operating Manual Senscient ELDS 1000 2000 Series Open Path Cross Duct Gas Detectors A 5170 0 Rev 15 ...
Страница 58: ...Installation Commissioning 58 Senscient ELDS Rev 15 GB 2 x Mounting Brackets ...
Страница 140: ...Certification 140 Senscient ELDS Rev 15 GB 9 1 2 Control Drawing CENELEC ATEX ...
Страница 142: ...Certification 142 Senscient ELDS Rev 15 GB 9 1 4 Control Drawing CSA US Canada ...
Страница 158: ...Appendix D Manufacturer s EC Declarations 158 Senscient ELDS Rev 15 GB 13 Appendix D Manufacturer s EC Declarations ...
Страница 159: ...Appendix D Manufacturer s EC Declarations Senscient ELDS Rev 15 159 GB ...
Страница 160: ...Appendix D Manufacturer s EC Declarations 160 Senscient ELDS Rev 15 GB ...
Страница 184: ...For local MSA contacts please visit us at MSAsafety com Because every life has a purpose ...