![MSA Senscient ELDS 1000 series Скачать руководство пользователя страница 165](http://html.mh-extra.com/html/msa/senscient-elds-1000-series/senscient-elds-1000-series_operating-manual_1846249165.webp)
Appendix E – HART Communications
Senscient ELDS™
Rev 15
165
GB
14.3.1 HART ELDS-Specific Information
As mentioned earlier, all Universal HART commands are supported by ELDS Receivers and
operate as defined in the relevant HART specifications. In the interests of clarity, this Appendix
does not attempt to describe all of the Universal HART commands and responses in detail. The
following table describes HART commands that will lead to responses that will contain ELDS-
specific information.
ELDS-Specific Information
Command
ELDS Data
Description
0 Read Unique Identifier Manufacturer ID
Senscient is 0x6067
ELDS 1000/2000 device is
0xE1D0
1 Read Primary Variable Units field / Primary Variable Units values are:
240 = ppm.m
241 = LFL.m
242 = LFL
The variable value is not limited
to the ELDS ‘full scale’ which is
normally imposed by the limited
range of the 4-20mA output
3 Read Dynamic
Variables and Loop
Current
1
st
Loop Current, gas values
and last SimuGas values
The loop current (in mA) is
explicitly coded in this HART
command, the 4 dynamic
variables contain the following
data:
PV, gas reading for 1
st
laser
SV, gas reading for 2
nd
laser
TV, SimuGas response 1
st
laser
QV, SimuGas response 2
nd
laser
12 Read Message
Firmware Revision
This returns a packed ASCII
message that identifies the
ELDS firmware revision. This
message is re-asserted every
time the Rx is powered up.
13 Read Tag, Descriptor,
Date
Last SimuGas result
The Tag field is user writable
via the HART connection and
can be used by the customer to
identify the ELDS unit if
required. The Descriptor
contains a message describing
the result of the last SimuGas
Auto trial (pass/fail) and the
date identifies the date of this
test. The content of the
descriptor are detailed fully
below in section 14.3.2
Содержание Senscient ELDS 1000 series
Страница 1: ...Operating Manual Senscient ELDS 1000 2000 Series Open Path Cross Duct Gas Detectors A 5170 0 Rev 15 ...
Страница 58: ...Installation Commissioning 58 Senscient ELDS Rev 15 GB 2 x Mounting Brackets ...
Страница 140: ...Certification 140 Senscient ELDS Rev 15 GB 9 1 2 Control Drawing CENELEC ATEX ...
Страница 142: ...Certification 142 Senscient ELDS Rev 15 GB 9 1 4 Control Drawing CSA US Canada ...
Страница 158: ...Appendix D Manufacturer s EC Declarations 158 Senscient ELDS Rev 15 GB 13 Appendix D Manufacturer s EC Declarations ...