![MSA Senscient ELDS 1000 series Скачать руководство пользователя страница 133](http://html.mh-extra.com/html/msa/senscient-elds-1000-series/senscient-elds-1000-series_operating-manual_1846249133.webp)
Specifications
Senscient ELDS™
Rev 15
133
GB
Gas
Open Path Ranges
Available Path Lengths
Cross Duct XD
Methane (CH
4
)
0-10% / 0-10% LFL
0-25% / 0-25% LFL
0-100% / 0-100% LFL
0.5 – 5m
Cross Duct XC
Methane (CH
4
)
0-25% / 0-25% LFL
0-100% / 0-100% LFL
0.5 – 5m
Ventilation Zone
Methane (CH
4
)
0-10% / 0-10% LFL
0-25% / 0-25% LFL
0-100% / 0-100% LFL
0.5 – 5m
Typical Performance - Open Path
Parameter
Value
Response Time
T90 ≤ 3 seconds (Typically)
T90 ≤ 5 seconds (H
2
S)
Repeatability
≤ ±5%FSD
Linearity
≤ ±5%FSD
Typical Performance – Cross Duct XD Units & Ventilation Zone VZ Units
Parameter
Value
Response Time
T
90
≤ 1 second
Repeatability
≤ ±5% FSD
Linearity
≤ ±5% FSD
Parameter
Value
Typical Performance – Cross Duct XC Units
Parameter
Value
Response Time
T
90
≤ 0.25 seconds
Repeatability
≤ ±5% FSD
Linearity
≤ ±5% FSD
Service Availability
The percentage of time that a unit will be available and operating (ignoring forced interruptions
such as blocked beam or power supply outages etc.), should be 99% or greater. In order to
achieve high service availability, ELDS™ OPGDs should be installed, operated and maintained in
accordance with the recommendations of this Technical Manual.
Содержание Senscient ELDS 1000 series
Страница 1: ...Operating Manual Senscient ELDS 1000 2000 Series Open Path Cross Duct Gas Detectors A 5170 0 Rev 15 ...
Страница 58: ...Installation Commissioning 58 Senscient ELDS Rev 15 GB 2 x Mounting Brackets ...
Страница 140: ...Certification 140 Senscient ELDS Rev 15 GB 9 1 2 Control Drawing CENELEC ATEX ...
Страница 142: ...Certification 142 Senscient ELDS Rev 15 GB 9 1 4 Control Drawing CSA US Canada ...
Страница 158: ...Appendix D Manufacturer s EC Declarations 158 Senscient ELDS Rev 15 GB 13 Appendix D Manufacturer s EC Declarations ...
Страница 159: ...Appendix D Manufacturer s EC Declarations Senscient ELDS Rev 15 159 GB ...
Страница 160: ...Appendix D Manufacturer s EC Declarations 160 Senscient ELDS Rev 15 GB ...
Страница 184: ...For local MSA contacts please visit us at MSAsafety com Because every life has a purpose ...