5 Mounting
Maschinenfabrik Reinhausen GmbH 2015
114
4427410/00 EN
OILTAP® R
2.
Screw on-load tap-changer head cover using screws and safety ele-
ments.
Figure 140: On-load tap-changer head cover
Drying the on-load tap-changer
1.
Connect pipe connections R and Q of on-load tap-changer head to the
kerosene vapor lead using one shared lead.
2.
Seal off unused pipe connections with a suitable blank cover.
Figure 141: Shared lead
Vapor-phase drying in the transformer tank
1.
Supply kerosene vapor at a temperature of around 90 °C. Keep this
temperature constant for 3 to 4 hours.
2.
Increase the kerosene vapor temperature by approx. 10 °C/hour to the
desired final temperature (125 °C maximum on the on-load tap-chang-
er).
3.
Vacuum dry on-load tap-changer at between 105 °C and maximum 125
°C for at least 50 hours.
4.
Residual pressure of no more than 10
-3
bar.
Closing kerosene drain plug
1.
Remove diverter switch insert.
2.
Close kerosene drain plug with extended socket wrench by turning
clockwise (tightening torque 20 Nm).