Installation
11
2.8 Environmental Data
Model (VMX-SGY-I-)
17
22
29
35
41
55
66
80
100
Frame Size
1
Heat output @ FLC (W)
25.5
33
43.5 52.5 61.5 82.5 99
120 150
Weight kg [lb]
3.9 [8.6]
4.2 [9.26]
Model (VMX-SGY-I-)
132
160 195
242
302
361 430 500 -
Frame Size
2
3
-
Heat output @ FLC (W)
198
240 293
363
453
542 645 750 -
Weight kg [lb]
6.7 [14.78] 7.0 [15.44] 17.0 [37.5]
22.0 [48.5]
-
Model (VMX-SGY-I-)
17 to 500
Ambient Operating Temp.
-20°C [-4°F] to 50°C [122°F]; above 50°C derate linearly by 4% of
VMX-Synergy Plus
TM
Ie per °C to a maximum of 60°C (140°F)
Transportation and Storage
Temperature
-25°C to 70°C [-13°F to 158°F] continuous
Humidity
Max 85% non-condensing, not exceeding 50% @ 40°C [104°F]
Maximum Altitude
1,000m [3281ft]; above 1000m derate by 1% of VMX-Synergy Plus
TM
Ie per 100m (328ft) to a maximum altitude of 2,000m (6562ft)
Environmental Rating
Main Circuit: IP00 (IP20 with optional finger guards for sizes 1&2 only);
Control Circuit: IP20; No corrosive gases permitted