7-30
Motorola RF Switch System Reference Guide
1. Select
Management Access
>
Users
from the main menu tree.
The Users screen displays.
2. Select the
Authentication
tab.
3. Click the
Add
button at the bottom of the screen.
4. Configure the following Radius Server attributes:
5. Refer to the
Status
field for the current state of the requests made from applet. This field displays error
messages if something goes wrong in the transaction between the applet and the switch.
6. Click on
OK
to complete the addition of the Radius Server.
7. Click
Cancel
to revert back to the last saved configuration without saving any of your changes.
7.6.2.3 External Radius Server Settings
When using an external Radius Server with the switch, ensure that the following values are configured on
your server to ensure maximum compatibility with the switch.
Radius Server IP
Address
Provide the IP address of the external Radius server. Ensure this address is a valid
IP address and not a DNS name.
Radius Server Port
Enter the TCP/IP port number for the Radius Server. The port range available for
assignment is from 1 - 65535.
Number of retries to
communicate with
Radius Server
Enter the maximum number of times for the switch to retransmit a Radius Server
frame before it times out the authentication session. The available range is
between 0 - 100.
Time to wait for
Radius Server to reply
Enter the maximum number of times the switch can retransmit a Radius Server
frame before it times out of the authentication session. The available range is
between 0 - 100.
Encryption key shared
with Radius Server
Enter the encryption key the switch and Radius Server share and must validate
before the user based authentication provided by the Radius Server can be
initiated.
Содержание RFS Series
Страница 1: ...M Motorola RFS Series Wireless LAN Switches WiNG System Reference Guide ...
Страница 10: ...TOC 8 Motorola RF Switch System Reference Guide ...
Страница 56: ...2 8 Motorola RF Switch System Reference ...
Страница 334: ...5 52 Motorola RF Switch System Reference 2 Select the MU Status tab ...
Страница 510: ...7 32 Motorola RF Switch System Reference Guide ...
Страница 534: ...8 24 Motorola RF Switch System Reference Guide ...
Страница 570: ...C 14 Motorola RF Switch System Reference Guide ...
Страница 589: ......
Страница 590: ...MOTOROLA INC 1303 E ALGONQUIN ROAD SCHAUMBURG IL 60196 http www motorola com 72E 132942 01 Revision C December 2010 ...