A p p l i c a t i o n V i e w s
S u p p o r t e d A p p l i c a t i o n s
D e v i c e M a n a g e m e n t
Page 78
M o t o r o l a V a n g u a r d
signallingType
Select the E&M signalling type. Valid values are:
i
,
ii
,
iii
,
v
, and
nc
. This parameter is displayed
for DSPM/E&M and skipped for FXS, FXO, and
all virtual port types.
ELeadFilter
Selection for E lead filter enable or disable option.
This parameter is displayed for DSPM/E&M and
skipped for FXS, FXO, and all virtual port types.
Valid values are:
enabled
,
disabled
, and
nc
.
HybridFXS
Hybrid balance filters and termination type based
on country.
Table 19
displays the valid filters:
This parameter is displayed for DSPM/FXS and
skipped for DSPM/E&M, DSPM/HC(FXO) and all
virtual port types.
HybridEAndM2
Hybrid balance filters and termination type based
on country. (Only for E&M-2wire interfaces.)
Table 20
displays valid filters and descriptions:
Table 19:
Hybrid FXS Filters
Filter
Description
sixHundred
600 ohm interface for USA, Japan and
Ireland.
Canada
600 ohms with 2.16 uF.
Germany
220 ohms in series with (820 ohms in
parallel with 115nF).
UK
300 ohms in series with (1K ohms in
parallel with 220nF).
Belgium
150 ohms in series with (830 ohms in
parallel with 72nF).
France
215 ohms in series with (1K ohms in
parallel with 137nF).
nc
Skipped during configuration.
Table 19:
Hybrid FXS Filters
Filter
Description