A p p l i c a t i o n V i e w s
S u p p o r t e d A p p l i c a t i o n s
D e v i c e M a n a g e m e n t
Page 103
M o t o r o l a V a n g u a r d
Call Statistics View
Access:
In the X.25 Configuration Table, click the Calling
Table button.
This view contains a table that provides call
statistics for each of the device’s X.25 ports.
Column headings are as follows:
PortNo
Identifies a particular X.25 port.
Destn
All calls entering this port will be routed to any
destination specified in this column, irrespective
of route selection table entries.
PortAddr
For X.25 links with the REGO or REGI option
selected, this address is inserted into the calling
address field of the outbound or inbound call
packet. For MUX links the subaddress of the
channel is appended to this address and inserted
into the calling address field of the call packet.
IdleTime
The time in seconds that the port must be idle (no
calls) before being automatically disconnected. A
value of zero disables the Idle Disconnect feature.
This feature may only be enabled on
DIMO/DIMOa/DIMOb/DIMOv/SIMPv ports with
the BKUP option selected.
Security
For V.25bis backup ports, the type of call security
to use prior to the link being detected up: if value
is
disable
, both incoming and outgoing calls are
allowed; if
enable
, only outgoing calls are allowed
and incoming calls will be immediately
terminated. This parameter is only used with Link
Backup.
TCN_ON
Throughput Class Negotiation enabled. The
throughput class negotiation facility in an
inbound call will be allowed. The throughput
class negotiation facility will always be
included in outbound calls and call
accepted/connected when this parameter is
set. The facility is passed onward to the
destination in the call packet transparently
and does not alter the handling of the SVC
data within the node.
TCN_OFF
Throughput Class Negotiation disabled.
Inbound calls containing the throughput
class negotiation facility will be cleared. The
throughput class negotiation facility will not
be present in outbound calls and call
accepted/connected when this parameter is
set.
Table 38:
Facility Subscription Codes
Code
Description