Part Number: 000016427 Rev 00 08/2020 75
Determining Which Safety Limit Stopped the Ice Machine:
When a safety limit condition
causes the ice machine to stop, the harvest light on the control board continually flashes
on and off. Use the following procedures to determine which safety limit has stopped the
ice machine.
1. Move the toggle switch to OFF.
2. Move the toggle switch back to ON.
3. Watch the harvest light. It will flash one or two times, corresponding to safety limits 1
and 2, to indicate which safety limit stopped the ice machine.
After safety limit indication, the ice machine will restart and run until a safety limit is
exceeded again.
Safety Limit Notes
• A safety limit indication is completed before the water pump starts. Water contacting
the ice thickness probe in the freeze cycle will cause the harvest light to flash. Do not
mistake a harvest light flashing in the freeze cycle with a safety limit indication.
• A continuous run of 100 harvests automatically erases the safety limit code.
• The control board will store and indicate only one safety limit – the last one exceeded.
• If the toggle switch is moved to the OFF position and then back to the ON position prior
to reaching the 100-harvest point, the last safety limit exceeded will be indicated.
• If the harvest light did not flash prior to the ice machine restarting, then the ice machine
did not stop because it exceeded a safety limit.
Содержание PKM0335
Страница 2: ......
Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 64: ...64 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 98: ...98 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 130: ...130 Part Number 000016427 Rev 00 08 2020 Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 131: ......
Страница 132: ...Katom 305 Katom Drive Kodak Tennessee 37764 Part Number 000016427 Rev 00 08 2020 ...