Part Number: 000016427 Rev 00 08/2020 85
Harvest Valve
General
The harvest valve is an electrically operated valve that opens when energized, and closes
when de-energized.
Normal Operation
The valve is de-energized (closed) during the freeze cycle and energized (open) during
the harvest cycle. The valve is positioned between the receiver and the evaporator and
performs two functions:
1. Prevents refrigerant from entering the evaporator during the freeze cycle.
The harvest valve is not used during the freeze cycle. The harvest valve is de-
energized (closed) preventing refrigerant flow from the receiver into the evaporator.
2. Allows refrigerant vapor to enter the evaporator in the harvest cycle.
During the harvest cycle, the harvest valve is energized (open) allowing refrigerant
gas from the discharge line of the compressor to flow into the evaporator. The heat is
absorbed by the evaporator and allows release of the ice slab.
Exact pressures vary according to ambient temperature and ice machine model. Harvest
pressures can be found in the Cycle Time/24 Hour Ice Production/Refrigerant Pressure
Charts in this book.