Part Number: 000016427 Rev 00 08/2020 63
Operational Analysis
1
2
3
4
Freeze Cycle
Suction Pressure
________ ______ ______
1 minute Middle End
If suction pressure is High or Low refer to freeze cycle high
or low suction pressure problem checklist to eliminate
problems and/or components not listed on this table before
proceeding.
Suction
pressure is
High
Suction
pressure is
Low
Suction
pressure is
High
Suction
pressure is
High
Harvest Valve
The harvest
valve inlet is
HOT
and
The
compressor
discharge line
is
HOT
The harvest
valve inlet is
COOL
and
The
compressor
discharge line
is
HOT
The harvest
valve inlet is
COOL
and
The
compressor
discharge line
is
COOL
The harvest
valve inlet is
COOL
and
The
compressor
discharge line
is
HOT
Discharge Line Temp.
Record freeze cycle
discharge line temp at the
end of freeze cycle.
Discharge line
temp
150°F
(66°C) or
higher
at the
end of freeze
cycle
Discharge line
temp
150°F
(66°C) or
higher
at the
end of freeze
cycle
Discharge line
temp
less than
150°F (66°C)
at the end of
freeze cycle
Discharge line
temp
150°F
(66°C) or
higher
at the
end of freeze
cycle
Final Analysis
Enter total number of boxes
checked in each column.
Harvest Valve
Leaking
Low On
Charge
-or-
TXV Starving
TXV Flooding Compressor
Содержание PKM0335
Страница 2: ......
Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 64: ...64 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 98: ...98 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 130: ...130 Part Number 000016427 Rev 00 08 2020 Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 131: ......
Страница 132: ...Katom 305 Katom Drive Kodak Tennessee 37764 Part Number 000016427 Rev 00 08 2020 ...