Part Number: 000016427 Rev 00 08/2020 67
Step 3
Disconnect the ice thickness probe from the control board terminal. Clip the
jumper wire to the terminal on the control board and any cabinet ground. Monitor the
harvest light.
EVAPORATOR
ICE THICKNESS
PROBE
PROBE
CONNECTION
GROUND
JUMPER WIRE
BIN SWITCH
LIGHT (GREEN) HARVEST LIGHT
(RED)
SV1592J
Step 3 Jumper wire connected from control board terminal to ground
Monitoring Harvest Light
Correction
The harvest light comes on, and 6-10
seconds later, ice machine cycles from freeze
to harvest.
The ice thickness probe is causing the
malfunction.
The harvest light comes on but the ice
machine stays in the freeze sequence.
The control circuitry is functioning properly.
The ice machine is in a six-minute freeze
time lock-in (verify step 1 of this procedure
was followed correctly).
The harvest light does not come on.
The control board is causing the
malfunction.