Part Number: 000016427 Rev 00 08/2020 37
PKM0335/PKM0425/PKM0535 Models
Control Board Test Mode
NOTE: The water curtain/bin switch can be open or closed and does not affect the
operation of the test mode.
To enter the test mode, move the toggle switch to off, then press and hold the test button
on the control board for 3 seconds. The control board test mode performs the following
functions for a 2-minute time period:
• Energizes all control board relays
• Energizes all control board lights
After 2 minutes, the control board will automatically initiate and complete one ice-making
cycle, then stop.
Canceling a test cycle:
To cancel a test cycle, press the test button a second time.
Restarting a test cycle:
The test cycle will restart each time the test button is pressed for a 3-second time period.
Troubleshooting