106
Part Number: 000016427 Rev 00 08/2020
Check Procedure
Disconnect electrical power to the ice machine at the electrical service disconnect.
Verify fan motor windings are not open or grounded, and fan spins freely.
Connect manifold gauge to ice machine.
Hook voltmeter in parallel across the fan cycle control, leaving wires attached.
Reconnect electrical power to the ice machine and Cycle the toggle switch On.
Wait until water flows over the evaporator then refer to chart below.
System Pressure:
Reading Should Be:
Fan Should Be:
above cut-in
0 volts
running
below cut-out
line voltage
off