![Morgana Digifold Pro CB Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/morgana/digifold-pro-cb/digifold-pro-cb_service-manual_1833955065.webp)
Page 65
14.5.
14.6.
14.7.
15.1.
Repeat this procedure from 14.3 until the desired result is achieved and then
return to the Run Screen.
With the motors running, operate the Compressor Switch to start the Compressor.
From the Run Screen start the Vacuum Drum & Suction. Hold a Test Sheet over the
drum (do not allow the sheet to be fed) & ensure the drum does not stop. If it stops
check the
on the Single Stepper Driver PCB is set
correctly (Set Switches as shown on the Wiring Diagram on page 85)
Enter the Engineering Tools Section & Select "
".
Alter the setting as required. This setting controls the length of time that the
suction is on for before the drum starts to rotate. Results have shown that the optimum
setting is 03.
The DigiFold is equipped with a total of four Sensors & three Detectors. They all have indicator
LED's on the Main Control Board & their operation can be checked from the Advanced Tools
Menu. The sensitivity of the Sensors can be adjusted individually by adjusting the appropriate
Potentiometer on the Main Control Board using a small insulated electrical screwdriver. The
Detectors have no adjustments.
Check the operation of each Sensor or Detector in turn by entering the Tools Menu &
operate
Operate each sensor manually.
The
registers the lead edge of the sheet to within 0.1mm. Its correct
setting is extremely critical to the performance of the machine and
15.2 Ensure the Red LED3 on the Main Control Board is Off. Place an 80gsm
sheet on the Loading Table with its Lay Edge against the Fixed Side Lay. Slide the
sheet up to the Input Rollers & rotate the machine by hand to drive the sheet
through the Lead Edge Sensor - the display should read
and LED3
should come on as the sheet passes through the sensor beam.
15.3. Ensure there is no paper in the machine before setting the sensitivity. This is done by
adjusting the Crease Edge pot (VR4), on the Main Control Board. Turn the pot fully
anti-clockwise. Turn the pot clockwise until LED3 is just On, and then back anti-
clockwise 60° (i.e. about 10 clock minutes).
Vacuum Drum Torque Setting
Sensors and Detectors:-
'Sensor Check'.
'Paper Edge'
Vac Suck Trim
Lead Edge Sensor
any adjustment of its
sensitivity will require re-calibration of the machine.
15.
Note.-
If LED3 does not come On, when VR4 is set between the 6 o’clock and 9 o’clock positions the
Lead Edge Sensor should be replaced. (See Below)
VR4
VR4
VR4
Fully anti-clockwise Posn.
6 o’clock Posn.
9 o’clock Posn.
Digifold Pro
SYSTEM
Содержание Digifold Pro CB
Страница 7: ...Page 7 SYSTEM BLANK PAGE Digifold Pro ...
Страница 13: ...Page 13 SYSTEM Digifold Pro ...
Страница 17: ...Page 17 SYSTEM BLANK PAGE Digifold Pro ...
Страница 21: ...Page 21 SYSTEM Layedge Side Operator Side Digifold Pro ...
Страница 37: ...SYSTEM Page 37 BLANK PAGE Digifold Pro ...
Страница 39: ...Page 39 SYSTEM Digifold Pro ...
Страница 53: ...Page 53 BLANK PAGE Digifold Pro SYSTEM ...
Страница 55: ...Page 55 Digifold Pro SYSTEM ...
Страница 61: ...Page 61 Digifold Pro SYSTEM ...
Страница 73: ...Page 73 Digifold Pro SYSTEM ...
Страница 79: ...Page 79 Digifold Pro SYSTEM ...
Страница 88: ...Page 88 CREASING FOLDING Section N BL YEL ...
Страница 92: ...Page 92 CREASING FOLDING Mod No Rev Mod Description Date Mod By REVISION HISTORY ...