Chapter 5: Optional hardware installation
70
MobileView PENTA Installation Manual
Calibrating the accelerometer
Before installation, the X, Y, and Z axes of the accelerometer are calibrated to
the force of gravity to both a maximum and minimum.
To calibrate the accelerometer:
1. Click Calibrate Accelerometer.
2. Rotate the accelerometer on each axis to comply with calibration instructions.
When it reaches max/min, click OK.
Viewing accelerometer data
After completing the calibration procedure, you can view the accelerometer data.
To view the data, click View Accelerometer. With the accelerometer on a flat
surface, the minimum and maximum values shown for the Z axis should be near
1; and the minimum and maximum values for the X and Y axes should near 0, as
shown in Figure 50 below.
Figure 50: Accelerometer data
Configuring DVR accelerometer alarm events
Once the accelerometer is calibrated, you can close the MobileView PENTA
Hardware Monitor program and configure the DVR to perform certain functions
based on accelerometer activation readings using Video Manager. See the
MobileView Video Manager User Manual
for detailed information on accessing
and configuring alarm events. The instructions in this manual refer only to
accelerometer alarm event configuration.
Содержание PENTA
Страница 1: ...PENTA Installation Manual UM TR 1210 ...
Страница 5: ...MobileView PENTA Installation Manual iii ...
Страница 6: ......
Страница 23: ...Chapter 2 Camera installation MobileView PENTA Installation Manual 17 ...
Страница 24: ...Chapter 2 Camera installation 18 MobileView PENTA Installation Manual ...
Страница 72: ......
Страница 92: ...Chapter 6 Testing 86 MobileView PENTA Installation Manual ...
Страница 105: ...Appendix A Checklists and worksheets MobileView PENTA Installation Manual 99 ...
Страница 106: ......
Страница 114: ......