Trouble type
Questions/Trouble
Remedy
No.
Error compensation
The machine only moves to
"10081230", although positioning
with a command value of
"10081234" carried out.
How can the error be
compensated?
The following values are currently
set.
•
"
Pr.2
No. of pulses per
rotation
"
8192PLS
•
"
Pr.3
Movement amount
per rotation" 8000
µ
m
Reset
"
Pr.3
"
and
"
Pr.2
"
in the following order.
1) Calculate "8192/8000
×
10081234/10081230".
2) Obtain the reduced value.
3) Set the numerator in "
Pr.3
Movement amount per
rotation", and the denominator in "
Pr.2
No. of pulses
per rotation".
18
When carrying out a count-method
machine OPR, the message
"Leave Sufficient Distance From
The OP Position To The Near-
Point Dog OFF." appears. Is there
a problem
if the distance is short?
The near-point dog must be set to turn OFF at a position
after the OP is passed.
(When the OPR is started on the near-point dog in a
count-method machine OPR, the machine enters a
normal OPR operation after returning to the near-point
dog OFF region.)
(If the near-point dog is turned OFF before the OP, and
the machine OPR is started between the near-point dog
OFF position and the OP, the machine will mistakenly
interpret that its current position is before the near-point
dog ON position, and it will pass over the OP and
continue moving.)
19
In the near-point dog method
machine OPR, the stop positions
are not uniform.
Carry out the following measures.
1) Separate the near-point dog signal and zero signal
detection positions.
2) Lower the values in
"
Pr.46
OPR speed
"
and
"
Pr.47
Creep speed
"
.
3) Confirm whether the zero signal and near-point dog
signal turn ON normally.
4) Check that there is no play (backlash) in the machine
system.
20
Can the OPR be carried out with
the OPR retry function when it is
started with the near-point dog ON
and the limit (LS) OFF?
A "Hardware stroke limit error" will occur and the
operation will not be carried out.
(The machine will interpret any position where the near-
point dog is ON as being within the working range, and
that the limit (LS) is ON.)
21
Are ABS and INC positioning
possible without carrying out an
OPR?
They are possible.
In this case, the position where the power is turned ON is
handled as the current feed value "0".
22
OPR
After an OPR, the OPR request
flag sometimes turns ON for no
apparent reason.
The OPR request flag turns ON in the following cases.
1) When the power is turned ON.
2) When the absolute system has not been set.
3) When the OPR has not been executed at the absolute
position system.
4) When an OPR operation starts.
If no problem is found when the above are checked, then
it is possible that the communication is being interrupted
by "a fault in the bus cable", "noise influence", etc.
23
Содержание QD75M1
Страница 17: ...MEMO...
Страница 71: ...3 20 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS MEMO...
Страница 87: ...4 16 MELSEC Q 4 INSTALLATION WIRING AND MAINTENANCE OF THE PRODUCT MEMO...
Страница 98: ...5 11 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 104: ...5 17 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 108: ...5 21 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 112: ...5 25 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 122: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 134: ...5 47 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 178: ...5 91 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 184: ...5 97 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 190: ...5 103 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 249: ...5 162 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 270: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 271: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 272: ...6 23 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 273: ...6 24 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 274: ...6 25 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 275: ...6 26 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 276: ...6 27 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 277: ...6 28 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 278: ...6 29 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 279: ...6 30 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 280: ...6 31 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 281: ...6 32 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 282: ...6 33 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 283: ...6 34 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 284: ...6 35 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 285: ...6 36 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 286: ...6 37 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 287: ...6 38 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 288: ...6 39 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 289: ...6 40 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 290: ...6 41 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 291: ...6 42 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 292: ...6 43 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 293: ...6 44 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 294: ...6 45 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 295: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 296: ...6 47 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 297: ...6 48 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 298: ...6 49 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 299: ...6 50 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 300: ...6 51 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 301: ...6 52 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL...
Страница 328: ...7 7 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Страница 332: ...7 11 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Страница 339: ...MEMO...
Страница 529: ...11 36 MELSEC Q 11 MANUAL CONTROL MEMO...
Страница 621: ...12 92 MELSEC Q 12 CONTROL SUB FUNCTIONS MEMO...
Страница 647: ...14 18 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO...
Страница 755: ...Appendix 2 MELSEC Q APPENDICES MEMO...
Страница 758: ...Appendix 5 MELSEC Q APPENDICES Axis address mm inch degree PLS Axis address mm inch degree PLS...
Страница 764: ...Appendix 11 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 0 0...
Страница 766: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 3 0 0H 0H 80H 0000H 1 255 0 1 5H...
Страница 879: ...Index 14 MEMO...