Chapter 12
103
Technical data
Test outputs (X1, X2)
Number of outputs
2 (with 2 test pulse generators)
Output type
PNP semiconductor, short-circuit protected, short-
circuit monitoring (selectable)
Output voltage High
15 … 30 V DC (max. 1.8 V drop to terminal A1 of
CPU module)
Output resistance Low
≤
33
Ω
± 10 %, current limited at approx. 10 mA
Output current
Max. 120 mA at each test output (X1 or X2)
This means that a maximum of 8 testable sensor
cascades per module with max. 30 mA each are
possible.
The total current for the MELSEC-WS safety
controller for all outputs (X1…X8 and XY1…XY2) is
limited to a maximum of 1.28 A. This corresponds to
e.g. a maximum of 32 testable sensor cascades with
30 mA each plus 64 tactile sensors on inputs on
safety I/O modules with 5 mA each.
Test pulse rate (test period)
1 … 25 Hz, configurable
Test pulse duration (test gap)
1 … 100 ms, configurable
Load capacity
1
μ
F for test gap
≥
4 ms
0.5
μ
F for test gap 1 ms
Cable resistance
< 100
Ω
Safe outputs (Q1 … Q4)
Number of outputs
4
Output type
PNP semiconductor, short-circuit protected, short-
circuit monitoring (selectable)
Output voltage High
16 … 30 V DC (max. 0.8 V drop to terminal A1 of
this module)
Leakage current Low
Normal operation
Fault case
*4
Max. 0.1mA
Hardware version < V1.10.1
Max. 1.6 mA
Hardware version
≥
V1.10.1
Max. 2.0 mA
Output current
Max. 2.0 A
Total current I
sum
T
A
≤
45 °C
T
A
≤
55 °C
For UL/CSA applications
Max. 4.0 A
Max. 3.2 A
Max. 3.2 A
Test pulse width
*5
<
650
μ
s or disabled
*6*7
Test pulse rate
Max. 5 Hz
Capacitive load
≤
0.5
μ
F
Cable resistance
*8
Max.
5
Ω
(e.g. 100 m × 1.5 mm² = 1.2
Ω
)
Max. permitted coil energy without
external protection elements
*9
Hardware version V1.00.0
Hardware version
≥
V1.01.0
0.22 J
0.37 J
Response time
Depending on the logic configuration, for details see
Table 53.
Data interface
Backplane bus()
Содержание MELSEC-WS series
Страница 1: ...Safety Controller User s Manual WS0 CPU0 WS0 CPU1 WS0 CPU3 WS0 XTDI WS0 XTIO WS0 4RO ...
Страница 2: ......
Страница 20: ...Chapter 1 17 About this document visible or invisible radiation a combination of several risks and hazards ...
Страница 117: ...Chapter 14 114 Annex ...
Страница 134: ...Chapter 14 131 Annex ...
Страница 151: ......