Chapter 2
19
On safety
2.3 Correct
use
The MELSEC-WS safety controller fulfills the requirements of Class A
(industrial applications) in accordance with the “Interference emission” basic
specifications.
The MELSEC-WS safety controller is therefore only suitable for use in an industrial
environment and not for private use.
The MELSEC-WS safety controller may only be used within specific operating limits
(voltage, temperature, etc., refer to the technical data in Chapter 12) in the sense of
Section 2.2 and Section 7.1. It may only be used by specialist personnel and only at
the machine at which it was mounted and initially commissioned by qualified
personnel in accordance with the MELSEC-WS manuals.
All warranty claims against Mitsubishi Electric Corporation are forfeited in the case
of any other use, or alterations being made to the software or to devices, even as
part of their mounting or installation.
Pay attention to the safety notes and protective measures of the user’s manuals
(hardware) and Safety Controller Setting and Monitoring Tool Operating Manual!
Make sure that on the implementation of safety-related functional logic, the
regulations in the national and international standards are met, in particular the
control strategies and the measures for risk reduction that are stipulated for your
application.
The external voltage supply of the device must be capable of buffering brief mains
voltage failures of 20 ms as specified in IEC 60204.
The MELSEC-WS safety controller may not start up normally when power is
restored immediately after the external power supply has been shut off (within 5
seconds). To restore the power, wait for 5 or more seconds after power-off.
The modules of the MELSEC-WS safety controller conform to Class A, Group 1,
in accordance with EN 55011. Group 1 encompasses all ISM devices in which
intentionally generated and/or used conductor-bound RF energy that is required
for the inner function of the device itself occurs.
ATTENTION
ATTENTION
Содержание MELSEC-WS series
Страница 1: ...Safety Controller User s Manual WS0 CPU0 WS0 CPU1 WS0 CPU3 WS0 XTDI WS0 XTIO WS0 4RO ...
Страница 2: ......
Страница 20: ...Chapter 1 17 About this document visible or invisible radiation a combination of several risks and hazards ...
Страница 117: ...Chapter 14 114 Annex ...
Страница 134: ...Chapter 14 131 Annex ...
Страница 151: ......