Connecting devices
Function
Notes
Testing Possible
Series connection/
cascading
SICK Wx12/18/24/27, Vx18:
max. 2 pairs per input can be cascaded with test gap = 4 ms
(standard element)
max. 5 pairs per input can be cascaded with test gap = 12 ms
(customized element required)
SICK L21:
max. 10 pairs per input can be cascaded with test gap = 4 ms
(standard element)
max. 25 pairs per input can be cascaded with test gap = 8 ms
(customized element required)
SICK L27/L28:
max. 7 pairs per input can be cascaded with test gap = 4 ms
(standard element)
max. 18 pairs per input can be cascaded with test gap = 12 ms
(customized element required)
Take the max. line resistance of 100
Ω
into account.
For further information refer to the manual of the testable Type 2 single-beam
photoelectric safety switches.
4.3.2
Testable Type 4 single-beam photoelectric safety switches
Electrical connection: Example from Setting and Monitoring Tool with WS0-XTIO
SICK L41
Test input TE (transmitter) at X1
Output Q (receiver) at I1
Use protected or separate cabling for the test output of the module (X1...X8) to the test
input of the transmitter and for the output of the receiver to the safe input of the
module (I1...I8). Otherwise a cross circuit between these signals can inhibit the error
detection by this test.
Function
Notes
Testing Necessary
Series connection/
cascading
SICK L41:
max. 10 pairs per input can be cascaded with test gap = 4 ms
(standard element)
max. 25 pairs per input can be cascaded with test gap = 8 ms
(customized element required)
Take the max. line resistance of 100
Ω
into account
For further information refer to the manual of the testable Type 4 single-beam
photoelectric safety switches.
Table 42:
Functions of testable Type 2
single-beam photoelectric
safety switches
Note
Table 43:
Connection of testable Type
4 single-beam photoelectric
safety switches
Note
Table 44:
Functions of testable Type 4
single-beam photoelectric
safety switches
Note
Содержание MELSEC-WS series
Страница 1: ...Safety Controller User s Manual WS0 CPU0 WS0 CPU1 WS0 CPU3 WS0 XTDI WS0 XTIO WS0 4RO ...
Страница 2: ......
Страница 20: ...Chapter 1 17 About this document visible or invisible radiation a combination of several risks and hazards ...
Страница 117: ...Chapter 14 114 Annex ...
Страница 134: ...Chapter 14 131 Annex ...
Страница 151: ......