2. DEVICE RANGE THAT CAN BE SET
2.6 MELSEC-WS
2 - 15
2
DEVICE RA
NGE THA
T
CAN B
E SET
(4) When using offset specification
When setting devices using the offset function, the
device values are as follows.
(a) Input(I)
(b) Output(Q)
(c) Logic result(LQ)
(d) Logic input(LI)
(e) EFI input(EI)
(f)
EFI output(EQ)
Offset
+0
+1
+2
+3
+4
+5
+6
+7
+8 to +15
+0
I1.1
I1.2
I1.3
I1.4
I1.5
I1.6
I1.7
I1.8
Fixed to 0
(OFF)
+16
I2.1
I2.2
I2.3
I2.4
I2.5
I2.6
I2.7
I2.8
+32
I3.1
I3.2
I3.3
I3.4
I3.5
I3.6
I3.7
I3.8
+48
I4.1
I4.2
I4.3
I4.4
I4.5
I4.6
I4.7
I4.8
+64
I5.1
I5.2
I5.3
I5.4
I5.5
I5.6
I5.7
I5.8
+80
I6.1
I6.2
I6.3
I6.4
I6.5
I6.6
I6.7
I6.8
+96
I7.1
I7.2
I7.3
I7.4
I7.5
I7.6
I7.7
I7.8
+112
I8.1
I8.2
I8.3
I8.4
I8.5
I8.6
I8.7
I8.8
+128
I9.1
I9.2
I9.3
I9.4
I9.5
I9.6
I9.7
I9.8
+144
I10.1
I10.2
I10.3
I10.4
I10.5
I10.6
I10.7
I10.8
+160
I11.1
I11.2
I11.3
I11.4
I11.5
I11.6
I11.7
I11.8
+176
I12.1
I12.2
I12.3
I12.4
I12.5
I12.6
I12.7
I12.8
+192
Device range error
Offset
+0
+1
+2
+3
+4
+5
+6
+7
+8 to +15
+0
Q1.1
Q1.2
Q1.3
Q1.4
Q1.5
Q1.6
Q1.7
Q1.8
Fixed to 0
(OFF)
+16
Q2.1
Q2.2
Q2.3
Q2.4
Q2.5
Q2.6
Q2.7
Q2.8
+32
Q3.1
Q3.2
Q3.3
Q3.4
Q3.5
Q3.6
Q3.7
Q3.8
+48
Q4.1
Q4.2
Q4.3
Q4.4
Q4.5
Q4.6
Q4.7
Q4.8
+64
Q5.1
Q5.2
Q5.3
Q5.4
Q5.5
Q5.6
Q5.7
Q5.8
+80
Q6.1
Q6.2
Q6.3
Q6.4
Q6.5
Q6.6
Q6.7
Q6.8
+96
Q7.1
Q7.2
Q7.3
Q7.4
Q7.5
Q7.6
Q7.7
Q7.8
+112
Q8.1
Q8.2
Q8.3
Q8.4
Q8.5
Q8.6
Q8.7
Q8.8
+128
Q9.1
Q9.2
Q9.3
Q9.4
Q9.5
Q9.6
Q9.7
Q9.8
+144
Q10.1
Q10.2
Q10.3
Q10.4
Q10.5
Q10.6
Q10.7
Q10.8
+160
Q11.1
Q11.2
Q11.3
Q11.4
Q11.5
Q11.6
Q11.7
Q11.8
+176
Q12.1
Q12.2
Q12.3
Q12.4
Q12.5
Q12.6
Q12.7
Q12.8
+192
Device range error
Offset
+0
+1
+2
+3
+4
+5
+6
+7
+0
LQ0.0
LQ0.1
LQ0.2
LQ0.3
LQ0.4
LQ0.5
LQ0.6
LQ0.7
+8
LQ1.0
LQ1.1
LQ1.2
LQ1.3
LQ1.4
LQ1.5
LQ1.6
LQ1.7
+16
LQ2.0
LQ2.1
LQ2.2
LQ2.3
LQ2.4
LQ2.5
LQ2.6
LQ2.7
+24
LQ3.0
LQ3.1
LQ3.2
LQ3.3
LQ3.4
LQ3.5
LQ3.6
LQ3.7
+32
Device range error
Offset
+0
+1
+2
+3
+4
+5
+6
+7
+0
LI0.0
LI0.1
LI0.2
LI0.3
LI0.4
LI0.5
LI0.6
LI0.7
+8
LI1.0
LI1.1
LI1.2
LI1.3
LI1.4
LI1.5
LI1.6
LI1.7
+16
LI2.0
LI2.1
LI2.2
LI2.3
LI2.4
LI2.5
LI2.6
LI2.7
+24
LI3.0
LI3.1
LI3.2
LI3.3
LI3.4
LI3.5
LI3.6
LI3.7
+32
Device range error
Offset
+0
+1
+2
+3
+8 to +15
+0
EI110
EI111
EI112
EI113
Fixed to 0
+16
EI120
EI121
EI122
EI123
+32
EI130
EI131
EI132
EI133
+48
:
+240
Fixed to 0
+256
EI210
EI211
EI212
EI213
+272
EI220
EI221
EI222
EI223
+288
EI230
EI231
EI232
EI233
Device range error
+302
Device range error
Offset
+0
+1
+2
+3 to +15
+0
EQ10
EQ11
EQ12
Fixed to 0
+16
:
+240
Fixed to 0
+256
EQ20
EQ21
EQ22
Device range error
+272
Device range error
Содержание GOT2000 Series
Страница 2: ......
Страница 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 64: ......
Страница 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Страница 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Страница 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Страница 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Страница 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Страница 416: ......
Страница 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Страница 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Страница 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Страница 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Страница 542: ......
Страница 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Страница 568: ......
Страница 592: ...19 24 19 MULTI CHANNEL FUNCTION 19 3 GOT Side Settings Example Setting example for Ethernet connection 4 channels ...
Страница 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Страница 600: ......
Страница 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Страница 670: ...REVISIONS 2 ...
Страница 673: ......