9. MELSECNET/H CONNECTION (PLC TO PLC NETWORK), MELSECNET/10 CONNECTION (PLC TO
PLC NETWORK)
9 - 19
MELSECN
ET/H CON
N
ECTION
(P
LC
T
O
PLC NETWORK
),
MELSECN
E
T/10 CONNEC
T
ION (PLC T
O
PLC NETWORK)
9
Connecting to C Controller module
Use SW3PVC-CCPU-E Ver.3.05F or later for the
MELSECNET/H utility.
(1) Connection settings
: Necessary
: As necessary
: Not necessary
*1
If the IP address of the C Controller module has been
changed, input the changed IP address or host name.
*2
If the account of the C Controller module has been changed,
input the changed user name and password.
(2) MELSECNET/H Utility's [Parameter Settings]
(a) Parameter settings
: Necessary
: As necessary
: Not necessary
*1
Specify the same network No. as that of the GOT.
*2
Set the same mode setting as that of the GOT.
*3
Be sure to set the setting to perform the cyclic transmission.
POINT
POINT
POINT
When changing the network parameter
After writing the network parameter to the C Controller
module, either turn the C Controller module OFF and
then ON or reset it.
Item
Set value
Setting
necessity at
GOT connection
Target module
*1
192.168.3.3 (Default)
Write authority
Mark the checkbox
User name
*2
target
Password
*2
password
Detailed settings
-
Item
Set value
Setting
necessity at
GOT connection
Number of modules
1
Link device refresh cycle
(Use default value)
Routing parameter
Refer to (b).
Target module
1
Start I/O No.
0000
H
Channel No.
(Use default value)
Item
Set value
Setting
necessity at
GOT
connection
Oper
at
ion sett
ing
s
Network type
MNET/H mode
(Control station)
Network No.
*1
1
Group No.
0
Mode
*2
Online
Return
(Use default value)
Refresh parameters
(Use default value)
Net
w
ork rang
e assig
n
ment
Total stations
2
Assignment method
Start/End
L
B
/L
W
se
ttin
g
s
*3
Send
ra
nge
for
each st
at
ion
LB
Sta.
No.1
Start
0000
H
End
00FF
H
Sta.
No.2
Start
0100
H
End
01FF
H
S
end
ra
nge
for
each st
at
ion L
W
Sta.
No.1
Start
0000
H
End
00FF
H
Sta.
No.2
Start
0100
H
End
01FF
H
(LX/LY) settings
*3
No setting
Monitoring time
(Use default value)
Specify I/O master Sta.
*3
No setting
Specify reserved Sta.
No setting
Supplementary settings
(Use default value)
Содержание GOT2000 Series
Страница 2: ......
Страница 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 64: ......
Страница 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Страница 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Страница 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Страница 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Страница 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Страница 416: ......
Страница 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Страница 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Страница 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Страница 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Страница 542: ......
Страница 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Страница 568: ......
Страница 592: ...19 24 19 MULTI CHANNEL FUNCTION 19 3 GOT Side Settings Example Setting example for Ethernet connection 4 channels ...
Страница 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Страница 600: ......
Страница 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Страница 670: ...REVISIONS 2 ...
Страница 673: ......