19. MULTI-CHANNEL FUNCTION
19.3 GOT Side Settings
(2) Specifications
*1
MELSECNET/H connection, MELSECNET/10 connection, CC-Link IE Controller Network connection, CC-Link connection
(intelligent device station)
*2
Ethernet connection, MODBUS
®
/TCP connection
*3
Gateway function, MES interface function, Ethernet download
*4
Barcode reader, RFID controller, or personal computer (writing remote personal computer operation (serial), FA transparent
function, OS install, project data)
*5
GT15-QBUS2, GT15-ABUS2, GT15-J71GP23-SX, GT15-J71LP23-25, GT15-J71BR13, GT15-J61BT13
*6
GT27-V4-Z, GT27-R2-Z, GT27-V4R1-Z, GT27-ROUT-Z, GT27-MMR-Z
*7
GT15-75QBUSL, GT15-75QBUS2L, GT15-75ABUSL, GT15-75ABUS2L
Item
Specifications
Description
Max. number of
channels
4 channels
• In bus connection and network connection (*1),
only 1 channel can be set for one GOT.
• For the Ethernet connection (*2), up to 4
channels can be set.
• When the Ethernet interface built in the GOT is
used for connection other than communication
with a controller (*3), the connection is not
included in the count of the number of channels.
• The interface used for connecting to an external
device (*4) is not included in the count of the
number of channels.
Max. installable
number of
modules
3
• Multiple identical units can be installed only for
serial communication units.
• It is necessary to calculate the consumed
current.
(
This section
■
Allowable number
of stages
Max. 3 stages
(2 slots)
• A module that occupies 2 slots (*5, *6, *7) must
be installed at the first stage.
• For the video/RGB display, RGB output, and
multimedia function, install the unit indicated in
*6 at the first stage and the other units at the
second or later stage.
• When a unit indicated in *7 is used, other
extension units cannot be installed.
• The CF card unit must be installed on the last
stage, if used.
Содержание GOT2000 Series
Страница 2: ......
Страница 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 64: ......
Страница 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Страница 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Страница 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Страница 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Страница 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Страница 416: ......
Страница 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Страница 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Страница 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Страница 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Страница 542: ......
Страница 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Страница 568: ......
Страница 592: ...19 24 19 MULTI CHANNEL FUNCTION 19 3 GOT Side Settings Example Setting example for Ethernet connection 4 channels ...
Страница 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Страница 600: ......
Страница 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Страница 670: ...REVISIONS 2 ...
Страница 673: ......