15 - 32
15. SERVO AMPLIFIER CONNECTION
15.6 Device Range that Can Be Set
The following shows correspondences between virtual
devices for servo amplifier and data of the servo
amplifier used with the GOT.
(a) Servo amplifier request
(b) Operation mode selection
(c) Instruction demand (for test operation)
(d) Basic parameter/expansion parameter
*1
For the parameters prefixed by an asterisk (*), setting
becomes effective when the power is turned off once and
back on after setting the parameter data.
(e) Gain filter parameter
*1
For the parameters prefixed by an asterisk (*), setting
becomes effective when the power is turned off once and
back on after setting the parameter data.
Device
name
Item
Symbol
SP0
Status display data clear
―
SP1
Current alarm clear
―
SP2
Alarm history clear
―
SP3
External input signal prohibited
―
SP4
External output signal prohibited
―
SP5
External input signal resumed
―
SP6
External output signal resumed
―
Device
name
Item
Symbol
OM0
Normal mode (not test operation mode)
―
OM1
JOG operation
―
OM2
Positioning operation
―
OM3
Motorless operation
―
OM4
Output signal (DO) forced output
―
Device
name
Item
Symbol
TMB1
Temporary stop command
―
TMB2
Test operation (positioning operation) start
command
―
TMB3
Forward rotation direction
―
TMB4
Reverse rotation direction
―
TMB5
Restart for remaining distance
―
TMB6
Remaining distance clear
―
Device name
Item
Symbol
*1
PA1, PA1001
Control mode
*STY
PA2, PA1002
Regenerative brake option
*REG
PA3, PA1003
Absolute position detection
system
*ABS
PA4, PA1004
Function selection A-1
*AOP1
PA5, PA1005
Number of command input
pulses per revolution
*FBP
PA6, PA1006
Electronic gear numerator
(command pulse multiplying
factor numerator)
CMX
PA7, PA1007
Electronic gear denominator
(command pulse multiplying
factor denominator)
CDV
PA8, PA1008
Auto tuning mode
ATU
PA9, PA1009
Auto tuning response
RSP
PA10, PA1010
In-position range
INP
PA11, PA1011
Forward torque limit
TLP
PA12, PA1012
Reverses torque limit
TLN
PA13, PA1013
Command pulse input form
*PLSS
PA14, PA1014
Rotation direction selection
*POL
PA15, PA1015
Encoder output pulses
*ENR
PA16 to PA18,
PA1016 to PA1018
For manufacturer setting
―
PA19, PA1019
Parameter block
*BLK
Device name
Item
Symbol
*1
PB1, PB1001
Adaptive tuning mode
(Adaptive filter II)
FILT
PA2, PB1002
Vibration suppression control filter
tuning mode
(Advanced vibration suppression
control)
VRFT
PB3, PB1003
Position command acceleration/
deceleration time constant
(position smoothing)
PST
PB4, PB1004
Feed forward gain
FFC
PB5, PB1005
For manufacturer setting
―
PB6, PB1006
Ratio of load inertia moment to
servo motor inertia moment
GD2
PB7, PB1007
Model control gain
PG1
PB8, PB1008
Position loop gain
PG2
PB9, PB1009
Speed loop gain
VG2
PB10, PB1010
Speed integral compensation
VIC
PB11, PB1011
Speed differential compensation
VDC
PB12, PB1012
For manufacturer setting
―
PB13, PB1013
Machine resonance suppression
filter 1
NH1
PB14, PB1014
Notch form selection 1
NHQ1
PB15, PB1015
Machine resonance suppression
filter 2
NH2
PB16, PB1016
Notch form selection 2
NHQ2
PB17, PB1017
For manufacturer setting
―
PB18, PB1018
Low-pass filter setting
LPF
PB19, PB1019
Vibration suppression control
vibration frequency setting
VRF1
PB20, PB1020
Vibration suppression control
resonance frequency setting
VRF2
PB21 to PB22,
PB1021 to PB1022
For manufacturer setting
―
PB23, PB1023
Low-pass filter selection
VFBF
PB24, PB1024
Slight vibration suppression
control selection
*MVS
PB25, PB1025
Function selection B-1
*BOP1
PB26, PB1026
Gain changing selection
*CDP
PB27, PB1027
Gain changing condition
CDL
PB28, PB1028
Gain changing time constant
CDT
PB29, PB1029
Ratio of load inertia moment to
servo motor inertia moment at
changing gain
GD2B
PB30, PB1030
Position loop gain at changing
gain
PG2B
PB31, PB1031
Speed loop gain at changing gain
VG2B
PB32, PB1032
Speed integral compensation at
changing gain
VICB
PB33, PB1033
Vibration suppression control
vibration frequency setting for
changing gain
VRF1B
PB34, PB1034
Vibration suppression control
vibration resonance setting for
changing gain
VRF2B
PB35 to PB45,
PB1035 to PB1045
For manufacturer setting
―
Содержание GOT2000 Series
Страница 2: ......
Страница 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 64: ......
Страница 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Страница 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Страница 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Страница 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Страница 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Страница 416: ......
Страница 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Страница 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Страница 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Страница 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Страница 542: ......
Страница 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Страница 568: ......
Страница 592: ...19 24 19 MULTI CHANNEL FUNCTION 19 3 GOT Side Settings Example Setting example for Ethernet connection 4 channels ...
Страница 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Страница 600: ......
Страница 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Страница 670: ...REVISIONS 2 ...
Страница 673: ......