9
-
85
(3) Interrupt factors
Interrupt factors are listed in Table9.13.
*1: For available interrupt modules, refer to the following.
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
*2: For the Q02CPU, interrupt pointer I49 (the pointer dedicated to the high speed interrupt function) cannot be used.
*3: An interrupt is executed only when the operation mode after the error can be set to "Continue" in the PLC RAS tab of the PLC parameter
dialog box.
*4: For the Basic model QCPU, the interrupt pointer numbers are I50 to I127.
*5: This module can be a serial communication module, MELSECNET/H module, Ethernet module, or high-speed counter module.
For details, refer to the manual for each module.
*6: This module can be an intelligent communication module.
For details, refer to the manual for each module.
*7: When using an interrupt module together with the High Performance model QCPU, check the versions of the CPU module and GX
Developer. (
To use the intelligent function module interrupt (
Section 6.23), the intelligent function module setting (interrupt pointer
setting) is required in the "PLC system" tab of the PLC parameter dialog box. (
Section 8.1.1(2), Section 8.1.2(2))
Table9.13 Classification of interrupt factors
Interrupt factor
Interrupt
pointer No.
Description
CPU module type
Basic
model
QCPU
High
Performance
model QCPU
Process
CPU
Redun-
dant CPU
Interrupt by an interrupt module
*1
I0 to 15
Interrupt input from an interrupt module
Interrupt by a sequence-started
module
I16 to I27
Interrupt from an AnS/A series special
function module
*6
that is capable of starting an
interrupt in the CPU module.
Interrupt by the internal timer
I28 to 31
Fixed scan interrupt to execute synchronized
control with the operation cycle of a motion
controller
I49
*2
Interrupt by an error
*3
I32 to I39
Interrupt caused by an error which enables
continuation of sequence program operation.
I40, I41
Intelligent function module
interrupt
I50 to 255
*4
Interrupt from an intelligent function module
*5